MBGAS-3000CH Process Gas Analyzer

Part Number: MBGAS-3000CH Brand: ABB Group

ABB FT-IR Process Gas Analyzer

Price
$208.00 CAD
Stock
50+ In Stock

The MBGAS-3000CH is designed for continuous 24/7 operation without need for operator intervention. 

A comprehensive health monitoring program runs continuously in the background to ensure that all measurements are correct at any time. 

Efficient optics of the MBGAS-3000CH provide an excellent signal-to-noise performance, so that the detector does not require cooling for extra-sensitivity.

This greatly enhances the reliability and simplicity of the FT-IR measurement compared with process analyzers that require liquid nitrogen-cooled or Stirling-cooled detectors. Furthermore, all optical components are non-hygroscopic therefore avoiding moisture damage, eliminating the need for desiccant and reducing maintenance requirements.

The MBGAS-3000CH FT-IR process analyzer offers significant advantages over alternative technologies for analysis in process gas streams. 

Measurements are performed in real-time and multiple gas components can be measured simultaneously, with no requirement for carrier or reference gases. 

Installation is straightforward with minimal sample handling system.

Specifications

Brand

Spectral Range

  • 800 to 5,000 cm-1

Resolution

  • Apodized: 1 to 64 cm-1
  • Unapodized: < 0.7 cm-1

Detector

  • DTGS

Controller

  • PC Controlled (Option: Rack-Mounted Controller)

Signal Sampling

  • 24-bit ADC

Gas Cell

  • 1-liter gas cell, path length 3.20 m or 0.36 m, resistant mirrors, aluminum body, heatable up to 200° C, 1/4-inch Swagelok tubing connector

Beamsplitter Material

  • ZnSe (Non-Hygroscopic)

Communication

  • Ethernet Port (10/100 Mbps)

Enclosure

  • IP50 modular arrangement with gas cell module, interferometer module and Electronic box module

Mounting

  • Rack Mount or tray Mount
  • Brackets for Wall Mount

Power Supply

  • 100-240 Vac ± 10 %, 50 to 60 Hz ± 3 Hz

Power Consumption

  • 550 W at Power-Up and 200 W during Operation

Operating Temperature

  • 5° to 40° C

Humidity

  • 0 % to 95 % Relative Humidity, Non-Condensing

Certifications & Approvals

  • CE
  • TÜV

Stability

  • Temperature: < 1 % /°C
  • < 0.09 % transmission between consecutive 1-mn measurements @ 4 cm

Repeatability

  • Frequency: < 0.001 cm-1  @ 1918 cm-1

Accuracy

  • Frequency: < 0.06 cm-1 @ 1918 cm-1

Dimensions

  • 46 cm (W) x 85 cm (H) x 27 cm (D) excluding gas cell insulated enclosure (In wall mount orientation)

Weight

  • 35 kg

Documentation

show more