MEP 2600/MEP 2650 Electronic Pressure Switch
Brand: DanfossMEP 2600 and MEP 2650 Versions: For use in Mobile Hydraulic, Industrial Hydraulic and Air Compressor applications.
- Single output
- Output 1: Switch output:
- Hysteresis 1 to 8% of full scale
- Time constant 8 to 512 Milliseconds
- Immunity towards VDF
Specifications
Brand
Accuracy
- < ± 0.15 % of Full Scale/10K - Thermal Accuracy
- 1 % of Full Scale - (Including Non-Linearity, Hysteresis & Repeatability)
Ambient Temperature Range
- -40° to 125° C (-40° to 257° F)
Applications
- Air Compressors
- Mobile & Industrial Hydraulic Applications
- OEM Applications
Approvals & Certifications
- EMC EN 61326-2-3 (Emission, Immunity)
Approvals & Certifications
- EMC Directive, 2004/108/EC
- UL 508
BSP Connection
- G 1/4” A Male
Burst Pressure
- psi: 5801.5 to 58015 (MPa: 40 to 400, bar: 400 to 4,000)
Cable Length
- < 98.43 feet (< 30 metres)
Compensated Temperature
- -40° to 125° C (-40° to 257° F)
Delay Time
- 8 to 512 milliseconds - Switch Time Delay
Electrical Connectors
- Deutsch DT04 3-Pin
- DIN 3852-E
- M12 x 1 (EN 60947-5-2)
- Mini DIN Plug (EN 175301-803-C)
Electrical Contacts
- Normally Closed
- Normally Open
Enclosure, Body Material
- 304 Stainless Steel
- Plastic
Environmental Protection
- IP67
Gasket Material
- Viton
Hysteresis
- 1 to 8 % of Full Scale - Switch Hysteresis
Load
- 500 mA - Max.
- 600 mA - Max.
Materials of Construction
- Electrical Connection Material: Glass-Filled PBT 30 % GFR
- Electrical Connection Material: Gold (Au)-Plated
- Electrical Connection Material: Tin (Sn)-Plated
- Stainless Steel - Electrical Connection
NPT Connection
- 1/4”-18 Female NPT
- 1/4”-18 Male NPT
- 1/8”-27 Female NPT
- 1/8”-27 Male NPT
Overpressure & Static Pressure Limits
- Overload Pressure: psi: 30 to 2,100 (kPa: 206.8 to 14,480, bar: 2.06 to 144.8) for with Integrated Pulse-snubber
- Overload Pressure: psi: 30 to 3,000 (kPa: 206.8 to 20,680, bar: 2.06 to 206.8) for without Pulse-snubber
Pressure Cycles
- Durability, P: > 10 x 106 Cycles (10 to 90 % of Full Scale)
Process Connection Material
- 630 Stainless Steel (17-4 PH)
Process Temperature
- -40° to 125° C (-40° to 257° F) - Media Temperature
PT/PF/PS (JIS) Connection
- 1/4” PT Male
RFI/EMI Protection
- 100 V/m at 26 MHz to 1 GHz - EMC Immunity RF Field
- 3 V/m at 1.4 to 2.7 GHz - EMC Immunity RF Field
Set Point - Decreasing
- bar: 0 to 600
- kPa: 0 to 60,000
- psi: 0 to 8,702
Set Point - Increasing
- bar: 0 to 600
- kPa: 0 to 60,000
- psi: 0 to 8,702
Shock
- Shock Resistance: 100 G as Per EN 60068-2-27
Supply Voltage
- ± 33 V - Over/Reverse Voltage
- 8-32 V
Switch Type
- Transistor (PNP & NPN)
System Pressure
- bar: 3,000
- kPa: 300,000
- psi: 43,511
Temperature Range
- -55° to 150° C (-67° to 302° F) - Transport Temperature Range
Torque
- 30 to 35 Nm (265 to 310 In/Lbs)
UNF/UNC Connection
- 7/16”-20 UNF Male-2A
Vibration
- Sinusoidal Vibration: 20 G at 10 to 2,000 Hz (EN 60068-2-6) for Vibration Stability
Wetted Materials
- 630 Stainless Steel (17-4 PH)
- Mobile Hydraulic
- Industrial Hydraulic
- Air Compressor