PFVL141 Roll Force Load Cell

Brand: ABB Group

Due to its low impedance and high output signal power the Millmate Roll Force load cells has an extremely low sensitivity to insulation defects and maintains its measuring accuracy down to a 10Ωk insulation level.

The load cell output signal is calibrated for full interchangeability between load cells of the same type and size. 

The various types and the wide load range cover practically all conceivable roll force measurement applications.

Models matching criteria: 3
  • Product - Measuring Range 0.63 to 56 MN
100+ In Stock
$2,392.00 CAD
Does not ship to OH, United States
  • Product - Measuring Range 1.6 to 60 MN
50+ In Stock
$2,202.00 CAD
Does not ship to OH, United States
  • Product - Measuring Range 2 to 28 MN
22 In Stock
$1,594.00 CAD
Does not ship to OH, United States

Specifications

Nominal Load (MN)

  • PFVL 141C: 1.6, 2.5, 3.1, 4.0, 5.0, 6.3, 8.0, 10, 12.5, 14, 16, 18, 20, 22, 25, 28, 31, 35, 40, 45, 50, 51.5, 60
  • PFVL 141V: 0.63, 0.80, 1.0, 1.25, 1.6, 2.0, 2.5, 3.1, 4.0, 5.0, 6.3, 8.0, 10, 12.5, 14, 16, 18, 20, 22, 25, 28, 31, 35, 40, 45, 50, 56
  • PFVL 141R: 2.0, 2.5, 3.1, 4.0, 5.0, 6.3, 8.0, 10, 11.2, 12.5, 14, 16, 18, 20, 22.4, 25, 28

Measuring Rang

    Accuracy

    • ± 0.5 % of Fnom

    Linearity Deviation

    • ≤ ± 0.5 % of Fnom

    Hysteresis

    • ≤ 0.2 % of Fnom

    Repeatability Error

    • ≤ ± 0.1 % of Fnom

    Compression

    • 0.05 mm at Fnom

    Calibration Error

    • 0.1%

    Compensation for Minimum Error

    • 20° to 80° C

    Drift

    • Zero Point/Sensitivity: ≤ ± 0.01 %/°C

    Operating Temperature

    • -10° to 90° C

    Storage Temperature

    • -40° to 90° C

    Maximum Permitted Short-Term Temperature

    • 110° C
    show more