AV412 Dissolved Organics Monitor

Brand: ABB Group

AV412 UV254 dual-channel, low- and high-range dissolved organics monitors are designed for use on potable water treatment plants. 

In particular, they can be used to monitor the quality of the outlet from sand and carbon filters to provide a THM precursor measurement.

Long term field trials have shown that maintenance demands on these applications are minimal.
Features
  • Dual input gives two measurements in one instrument, each input can be either high range or low range
    • cost-effective
  • Surrogate color measurement
    • significant savings on operational costs through lower maintenance requirements
  • Savings on alum or ferric are achieved on potable water treatment plants
    • coagulation control cost saving
  • Less alum, less sludge
    • reduced sludge disposal costs
  • THM (trihalomethanes) precursor alert
    • provides advanced warning of increased risk of THM development
  • Automatic compensation for turbidity
    • reduces initial capital expenditure, minimizing operational costs
  • Reagentless operation
    • significant savings in operational expenditure
  • On-line diagnostics
    • cleaner failure, loss of signal, out of sample

Models matching criteria: 48
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 General
  • Serial Communication - PROFIBUS (Pending)
  • Power Supply - 12 to 30 Vdc
  • Manual - Italian
  • Wall - IP65 General - Wall-Mount Complete with Pipe-Mount Bracket
100+ In Stock
$668.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 N. American
  • Serial Communication - PROFIBUS (Pending)
  • Power Supply - 100 to 240 Vac, 50/60 Hz
  • Manual - Italian
  • Wall – IP65 N. American - Wall-Mount
100+ In Stock
$1,550.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 General
  • Serial Communication - None
  • Power Supply - 12 to 30 Vdc
  • Manual - Italian
  • Wall - IP65 General - Wall-Mount
100+ In Stock
$626.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 N. American
  • Serial Communication - PROFIBUS (Pending)
  • Power Supply - 100 to 240 Vac, 50/60 Hz
  • Manual - Frequency Input. Input for Dry Contact or NAMUR initiator
  • Wall – IP65 N. American - Wall-Mount
100+ In Stock
$2,244.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 General
  • Serial Communication - None
  • Power Supply - 100 to 240 Vac, 50/60 Hz
  • Manual - Italian
  • Wall - IP65 General - Wall-Mount
100+ In Stock
$1,534.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 N. American
  • Serial Communication - PROFIBUS (Pending)
  • Power Supply - 12 to 30 Vdc
  • Manual - English
  • Wall – IP65 N. American - Wall-Mount
100+ In Stock
$776.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 N. American
  • Serial Communication - None
  • Power Supply - 100 to 240 Vac, 50/60 Hz
  • Manual - English
  • Wall – IP65 N. American - Wall-Mount Complete with Pipe-Mount Bracket
100+ In Stock
$976.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 General
  • Serial Communication - None
  • Power Supply - 12 to 30 Vdc
  • Manual - English
  • Wall - IP65 General - Wall-Mount Complete with Pipe-Mount Bracket
50+ In Stock
$1,922.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 General
  • Serial Communication - PROFIBUS (Pending)
  • Power Supply - 12 to 30 Vdc
  • Manual - English
  • Wall - IP65 General - Wall-Mount Complete with Pipe-Mount Bracket
50+ In Stock
$843.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 N. American
  • Serial Communication - PROFIBUS (Pending)
  • Power Supply - 100 to 240 Vac, 50/60 Hz
  • Manual - English
  • Wall – IP65 N. American - Wall-Mount Complete with Pipe-Mount Bracket
50+ In Stock
$461.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 General
  • Serial Communication - None
  • Power Supply - 100 to 240 Vac, 50/60 Hz
  • Manual - English
  • Wall - IP65 General - Wall-Mount
50+ In Stock
$805.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 General
  • Serial Communication - PROFIBUS (Pending)
  • Power Supply - 100 to 240 Vac, 50/60 Hz
  • Manual - Frequency Input. Input for Dry Contact or NAMUR initiator
  • Wall - IP65 General - Wall-Mount Complete with Pipe-Mount Bracket
50+ In Stock
$2,308.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 General
  • Serial Communication - None
  • Power Supply - 12 to 30 Vdc
  • Manual - Italian
  • Wall - IP65 General - Wall-Mount Complete with Pipe-Mount Bracket
50+ In Stock
$1,600.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 General
  • Serial Communication - None
  • Power Supply - 12 to 30 Vdc
  • Manual - Frequency Input. Input for Dry Contact or NAMUR initiator
  • Wall - IP65 General - Wall-Mount
50+ In Stock
$2,294.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 General
  • Serial Communication - None
  • Power Supply - 100 to 240 Vac, 50/60 Hz
  • Manual - Frequency Input. Input for Dry Contact or NAMUR initiator
  • Wall - IP65 General - Wall-Mount Complete with Pipe-Mount Bracket
50+ In Stock
$628.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 N. American
  • Serial Communication - None
  • Power Supply - 12 to 30 Vdc
  • Manual - English
  • Wall – IP65 N. American - Wall-Mount
50+ In Stock
$469.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 N. American
  • Serial Communication - None
  • Power Supply - 12 to 30 Vdc
  • Manual - Italian
  • Wall – IP65 N. American - Wall-Mount
50+ In Stock
$2,405.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 General
  • Serial Communication - None
  • Power Supply - 100 to 240 Vac, 50/60 Hz
  • Manual - Italian
  • Wall - IP65 General - Wall-Mount Complete with Pipe-Mount Bracket
50+ In Stock
$447.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 N. American
  • Serial Communication - None
  • Power Supply - 100 to 240 Vac, 50/60 Hz
  • Manual - Frequency Input. Input for Dry Contact or NAMUR initiator
  • Wall – IP65 N. American - Wall-Mount
50+ In Stock
$555.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 General
  • Serial Communication - PROFIBUS (Pending)
  • Power Supply - 100 to 240 Vac, 50/60 Hz
  • Manual - English
  • Wall - IP65 General - Wall-Mount Complete with Pipe-Mount Bracket
50+ In Stock
$2,001.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 N. American
  • Serial Communication - PROFIBUS (Pending)
  • Power Supply - 100 to 240 Vac, 50/60 Hz
  • Manual - English
  • Wall – IP65 N. American - Wall-Mount
50+ In Stock
$2,011.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 N. American
  • Serial Communication - None
  • Power Supply - 12 to 30 Vdc
  • Manual - Frequency Input. Input for Dry Contact or NAMUR initiator
  • Wall – IP65 N. American - Wall-Mount Complete with Pipe-Mount Bracket
50+ In Stock
$448.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 N. American
  • Serial Communication - None
  • Power Supply - 12 to 30 Vdc
  • Manual - Frequency Input. Input for Dry Contact or NAMUR initiator
  • Wall – IP65 N. American - Wall-Mount
50+ In Stock
$70.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 N. American
  • Serial Communication - PROFIBUS (Pending)
  • Power Supply - 12 to 30 Vdc
  • Manual - Italian
  • Wall – IP65 N. American - Wall-Mount Complete with Pipe-Mount Bracket
50+ In Stock
$367.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 General
  • Serial Communication - PROFIBUS (Pending)
  • Power Supply - 12 to 30 Vdc
  • Manual - English
  • Wall - IP65 General - Wall-Mount
50+ In Stock
$1,279.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 N. American
  • Serial Communication - PROFIBUS (Pending)
  • Power Supply - 12 to 30 Vdc
  • Manual - English
  • Wall – IP65 N. American - Wall-Mount Complete with Pipe-Mount Bracket
50+ In Stock
$1,531.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 N. American
  • Serial Communication - None
  • Power Supply - 100 to 240 Vac, 50/60 Hz
  • Manual - Italian
  • Wall – IP65 N. American - Wall-Mount
50+ In Stock
$1,113.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 General
  • Serial Communication - None
  • Power Supply - 12 to 30 Vdc
  • Manual - English
  • Wall - IP65 General - Wall-Mount
50+ In Stock
$1,709.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 N. American
  • Serial Communication - None
  • Power Supply - 100 to 240 Vac, 50/60 Hz
  • Manual - English
  • Wall – IP65 N. American - Wall-Mount
50+ In Stock
$294.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 N. American
  • Serial Communication - PROFIBUS (Pending)
  • Power Supply - 12 to 30 Vdc
  • Manual - Frequency Input. Input for Dry Contact or NAMUR initiator
  • Wall – IP65 N. American - Wall-Mount Complete with Pipe-Mount Bracket
50+ In Stock
$618.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 General
  • Serial Communication - PROFIBUS (Pending)
  • Power Supply - 12 to 30 Vdc
  • Manual - Frequency Input. Input for Dry Contact or NAMUR initiator
  • Wall - IP65 General - Wall-Mount Complete with Pipe-Mount Bracket
50+ In Stock
$1,953.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 N. American
  • Serial Communication - None
  • Power Supply - 12 to 30 Vdc
  • Manual - English
  • Wall – IP65 N. American - Wall-Mount Complete with Pipe-Mount Bracket
25+ In Stock
$722.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 N. American
  • Serial Communication - None
  • Power Supply - 100 to 240 Vac, 50/60 Hz
  • Manual - Italian
  • Wall – IP65 N. American - Wall-Mount Complete with Pipe-Mount Bracket
25+ In Stock
$75.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 General
  • Serial Communication - None
  • Power Supply - 100 to 240 Vac, 50/60 Hz
  • Manual - Frequency Input. Input for Dry Contact or NAMUR initiator
  • Wall - IP65 General - Wall-Mount
25+ In Stock
$1,850.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 General
  • Serial Communication - PROFIBUS (Pending)
  • Power Supply - 100 to 240 Vac, 50/60 Hz
  • Manual - Italian
  • Wall - IP65 General - Wall-Mount
25+ In Stock
$1,606.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 General
  • Serial Communication - None
  • Power Supply - 100 to 240 Vac, 50/60 Hz
  • Manual - English
  • Wall - IP65 General - Wall-Mount Complete with Pipe-Mount Bracket
25+ In Stock
$1,538.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 General
  • Serial Communication - PROFIBUS (Pending)
  • Power Supply - 12 to 30 Vdc
  • Manual - Frequency Input. Input for Dry Contact or NAMUR initiator
  • Wall - IP65 General - Wall-Mount
25+ In Stock
$1,673.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 N. American
  • Serial Communication - PROFIBUS (Pending)
  • Power Supply - 100 to 240 Vac, 50/60 Hz
  • Manual - Frequency Input. Input for Dry Contact or NAMUR initiator
  • Wall – IP65 N. American - Wall-Mount Complete with Pipe-Mount Bracket
24 In Stock
$1,974.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 General
  • Serial Communication - None
  • Power Supply - 12 to 30 Vdc
  • Manual - Frequency Input. Input for Dry Contact or NAMUR initiator
  • Wall - IP65 General - Wall-Mount Complete with Pipe-Mount Bracket
19 In Stock
$1,372.00 CAD
Does not ship to OH, United States
  • Parameter 1 - Low Range Dissolved Organics
  • Parameter 2 - High Range Dissolved Organics
  • Transmitter Enclosure Type - Wall - IP65 General
  • Serial Communication - PROFIBUS (Pending)
  • Power Supply - 100 to 240 Vac, 50/60 Hz
  • Manual - Italian
  • Wall - IP65 General - Wall-Mount Complete with Pipe-Mount Bracket
19 In Stock
$1,726.00 CAD
Does not ship to OH, United States

Specifications

Range

  • Low Range: 0 to 20 mgl-1 C
  • High Range: 0 to 100 mgl-1 C

Linearity

  • Low Range: ± 2 % of Reading or 0.15 mgl-1 C whichever is greater
  • High Range: ± 2 % of Reading or 0.5 mgl-1 C whichever is greater

Reproductivity

  • Low Range: ± 0.15 mgl-1 C
  • High Range: ± 0.5 mgl-1 C

Flow Rate

  • Sample: 0.5 to 5 L/min-1

Sample Temperature

  • 0° to 40° C (32° to 104° F)

Sample Pressure

  • 3 bar (43.5 psi) Max.

Display

  • Dual 41/2-digit, 7-segment backlit LCD

Resolution

  • Output: 0.1 % at 10 mA, 0.05 at 20 mA
  • High Range: ± 0.1 mgl-1 C
  • Low Range: ± 0.01 mgl-1 C

Accuracy

  • ± 0.25 % FSD ± 5 % of Reading

Output

  • 0 to 10 mA, 0 to 20 mA or 4 to 20 mA

Power Supply

  • 100-240 Vac, 50/60 Hz (90-264 V)
  • Optional 12-30 Vdc

Power Consumption

  • 20 W

Environmental Protection

  • IP65

Cable Type

  • Standard 5 or 7 x M20 cable Glands
  • N. American 7 x knockouts suitable for 1/2 in. Hubble Gland

Operating Temperature

  • 0° to 50° C (32° to 122° F)

Storage Temperature

  • -25° to 75° C (-13° to 167° F)

Humidity

  • Up to 95 % Relative Humidity, Non-Condensing

Certifications & Approvals

  • UL
  • CE
  • EMC

  • Potable Water Treatment
show more