MBS 5100/MBS 5150 Pressure Transmitter
Brand: DanfossThe ship approved high accuracy block pressure transmitter is designed for use in almost all marine applications.
MBS 5150 with integrated pulse snubber is designed for use in marine applications with severe medium influences like cavitation, liquid hammer or pressure peaks and offers a reliable pressure measurement, even under harsh environmental conditions.
The transmitters can be easily mounted directly on the MBV 5000 block test valve or the threaded pressure connection can be used.
The flexible pressure transmitter programme covers a 4-20 mA output signal, absolute or gauge (relative) versions, measuring ranges from 0-1 to 0-600 bar with zero and span adjustment.
Excellent vibration stability, robust construction, and a high degree of EMC/EMI protection equip the pressure transmitter to meet the most stringent industrial requirements.
Specifications
Brand
Accuracy
- ≤ ± 0.1 % of Full Scale - Typical Including Non-Linearity, Hysteresis & Repeatability
- ≤ ± 0.3 % of Full Scale, Max.
Ambient Temperature Range
- -40° to 85° C (-40° to 185° F) - Depending on Electrical Connection
Applications
- Cavitation, Liquid Hammer or Pressure Peaks
- Hydraulic Applications
- Marine Applications
Approvals & Certifications
- EN 60770
- ABS
- BV
- CCS
- CE
- DNV
- EMC: EN 61000-6-3 (Emission), EN 61000-6-2 (Immunity)
- GL
- IEC
- KRS
- LRS
- NKK
- RINA
- RMRS
BSP Connection
- G 1/4” Female
Burst Pressure
- 6 x Full Scale [psi: 29,010 (MPa: 200, bar: 2,000) - Max.
Compensated Temperature
- 0° to 80° C (32° to 176° F)
Connection Material
- 316L Stainless Steel - Pressure Connection
Current
- 28 mA Typical - Current Limitation
Electrical Connectors
- PG11
- PG13.5
- PG9
- Plug Connection (EN 175301-803-A)
Enclosure, Body Material
- Anodized Aluminum (AIMgSiPb)
Environmental Protection
- IP65
Hysteresis
- ≤ ± 0.1 % of Full Scale
Insulation Resistance
- > 100 megaohms at 100 V
Measuring Range
- psi: 0 to 8,702 (kPa: 0 to 60,000, bar: 0 to 600)
Metric Connection
- M10 x 1 Female
Non-Linearity
- ≤ ± 0.2 % of Full Scale - BFSL
NPT Connection
- 1/4” NPT Female
O-Ring Material
- NBR - for Flange
Output
- Nominal 4-20 mA, 2-Wire - Short-Circuit Protected
Overpressure & Static Pressure Limits
- 6 x Full Scale [psi: 21,760 (kPa: 150,000, bar: 1,500) - Max.
Plug Material
- Glass-Filled Polyamide
Pressure Range
- bar: 0 to 600
- kPa: 0 to 60,000
- psi: 0 to 8,702
Pressure Type
- Absolute
- Gauge
Repeatability
- ≤ ± 0.1 % of Full Scale
Response Time
- < 35 milliseconds - Air & Gases (MBS 5150)
- < 4 milliseconds - Liquids with Viscosity < 100 cSt
Sensitivity
- ≤ ± 0.1 % of Full Scale/10K Typical - Thermal Sensitivity (Span) Shift
- ≤ ± 0.2 % of Full Scale/10K - Thermal Sensitivity (Span) Shift
Shock
- 1 metre Free Fall as Per IEC 60068-2-32
- 500 G, 1 millisecond as Per IEC 60068-2-27
Span & Zero Adjustments
- -5 to 10 % of Full Scale - Zero Point Adjustment
- -5 to 2.5 % of Full Scale - Zero Point Adjustment
- -5 to 20 % of Full Scale - Zero Point Adjustment
- -5 to 5 % of Full Scale - Span Adjustment
Span & Zero Effect
- ≤ ± 0.1 % of Full Scale/10K Typical
- ≤ ± 0.2 % of Full Scale/10K, Max.
Storage Temperature
- -50° to 85° C (-58° to 185° F)
Supply Voltage
- ≤ ± 0.01 % of Full Scale/10 V - Supply Voltage Dependency
- 10-32 Vdc - Polarity Protected
Temperature Range
- -40° to 85° C (-40° to 185° F) - Normal Sensor
Thermal Drift
- ≤ ± 0.1 % of Full Scale/10K Typical - Thermal Zero Point Shift
- ≤ ± 0.2 % of Full Scale/10K, Max.
Vibration
- Random Vibration: 7.5 G RMS, 5 to 1,000 Hz as Per IEC 60068-2-64
- Sinusoidal Vibration: 15.9 mm-pp, 5 to 25 Hz as Per IEC 60068-2-6
- Sinusoidal Vibration: 20 G, 25 to 2,000 Hz as Per IEC 60068-2-6
Wetted Materials
- 316L Stainless Steel, 1.4401
- Marine Applications
- Cavitation, Liquid Hammer or Pressure Peaks
- Hydraulic Applications