PGC5007 Total Sulfur Analyzer

Part Number: PGC5007 Brand: ABB Group

ABB Total Sulfur Analyzer

Price
$328.00CAD
Stock
25+ In Stock

The PGC5007 performs a Total sulfur analysis for a range of streams, liquid and vapor, from natural gas to gasoline and diesel.

A fixed volume of sample from the process stream is injected via a sample inject valve.

Air transports the sample into the furnace, where it oxidizes the sample to carbon dioxide, water and sulfur dioxide.

These components are separated using packed columns and pass into the Flame Photometric Detector (FPD), where the trace levels of Total Sulfur are measured.

Specifications

Brand

Environmental Protection

  • IP54 (NEMA 3 Equivalent)

Ambient Temperature

  • 0° to 50° C (32° to 122° F)

Humidity

  • 95 % Relative Humidity, Non-Condensing

Mounting

  • Wall: 32 mm (1.3 in.) from wall with brackets

EMI / RFI

  • Conforms to Class A industrial environment

Certifications & Approvals

  • CN / KO / RU: Ex px de IIB+H₂ T3 - T2, with X-purge Power interlock
  • ATEX / IEC: Zone 1: CE 0344, II2G, Ex py de IIB+H₂ T3 - T2, Zone 2: CE, II3G Ex nA nL de IIB+H₂ T3 - T2
  • CSA / NRTL: Class I, Div. 1, Gas groups B, C, D with Type Y-Purge, Class I, Div. 2, Gas groups B, C, D, Temperature code T3 - T2

Power Requirement

  • 100-240 Vac, 50 to 60 Hz

Power Consumption

  • Typical, varies with installed options
  • 1,200 W Startup
  • 900 W steady-state Operation

Tube Connection

  • Supply: 3/8” Tube, minimum

Pressure

  • Inlet: Set Point 69 kPa (10 psig) to 1,034 kPa (150 psig) Max.
  • Supply: 414 kPa (60 psig)

Flow Rate

  • Steady State: 127 to 147 L/min (4.5 to 5.2 ft³/min) at 20° C Y-purge Types

Material of Construction

  • Oven liner: Stainless Steel

Ambient Temperature

  • Oven: 30° to 180° C

Resolution

  • Setpoint: 1° C, 0.01 psig (Gas Control)

Stability

  • Ambient Range: ± 1.0° C
  • Temperature (Steady ambient): ± 0.1° C

Accuracy

  • 0 to 50 psig: 1.7 %
  • 50 to 100 psig: 2.7 %

Repeatability

  • ± 0.1 psig

  • A designation was assigned to the ABB On-line sulfur in fuel gas chromatograph (PGC2007) - ASTM Method D7041-04. 
  • The PGC2007 has now been updated to the PGC5000 Series PGC5007B Total Sulfur Analyzer.
  • This method provides industry the only on-line method with precision and bias data that is 2-5 times better than all other sulfur methods on the books. 
  • This is the only method to date that meets the requirements for low range (0-15 ppm) diesel compliance measurements.