AK100 H2 Purity and Purge Gas Monitor
Brand: ABB GroupThe H2 purity and purge gas monitor AK100 has been specifically designed to monitor hydrogen purity in hydrogen cooled generators.
The H2 purity and purge gas monitor AK100 provides a complete system for monitoring hydrogen purity during normal operation and purge gas monitoring during commissioning and decommissioning of the generator.
Features- Fully-certified for intrinsic safety – including European ATEX directive
- Failsafe design
- Proven technique based on over 80 years experience
- Full redundant measurement of hydrogen purity and purge gas
- Two programmable alarms
- Analog output for retransmission of hydrogen purity
- Sealed for life reference gas for very low maintenance
Displaying price & availability for Ohio, United States in CAD Change Location
3,024 models matching criteria
- Display Monitor Unit - Single 3-Range (H2 Purity & 2 x Purge Gas)
- Hydrogen Purity Range - 100 % to 85 % (Does Not Conform to ATEX Directive)
- Purge Gas - Argon
- GAs Analysis Panel - High Pressure for Closed Loop 10 Barg (145 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 230 V 50/60 Hz
- Special Features - None
- System Labels & Instruction Manuals - German
100+ In Stock
$109.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Separate H2 Purity & Purge Gas Displays
- Hydrogen Purity Range - 80/85 % to 100 %
- Purge Gas - Argon
- GAs Analysis Panel - High Pressure for Closed Loop 10 Barg (145 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 115 V 50/60 Hz
- Special Features - Special
- System Labels & Instruction Manuals - German
100+ In Stock
$187.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Single 3-Range (H2 Purity & 2 x Purge Gas)
- Hydrogen Purity Range - 100 % to 85 % (Does Not Conform to ATEX Directive)
- GAs Analysis Panel - Low Pressure & Flame Traps for Vent to Atmosphere 0.35 Barg (5 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 230 V 50/60 Hz
- Special Features - Special
- System Labels & Instruction Manuals - German
100+ In Stock
$223.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Single hydrogen Purity Display
- Hydrogen Purity Range - 100 % to 80 % (Does Not Conform to ATEX Directive)
- Purge Gas - Argon
- GAs Analysis Panel - High Pressure for Closed Loop 10 Barg (145 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 115 V 50/60 Hz
- Special Features - None
- System Labels & Instruction Manuals - Polish
100+ In Stock
$244.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Single 3-Range (H2 Purity & 2 x Purge Gas)
- Hydrogen Purity Range - 80/85 % to 100 %
- GAs Analysis Panel - Low Pressure & Flame Traps for Vent to Atmosphere 0.35 Barg (5 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 230 V 50/60 Hz
- Special Features - Special
- System Labels & Instruction Manuals - German
100+ In Stock
$582.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Single hydrogen Purity Display
- Hydrogen Purity Range - 100 % to 80 % (Does Not Conform to ATEX Directive)
- Purge Gas - None
- GAs Analysis Panel - Low Pressure & Flame Traps for Vent to Atmosphere 0.35 Barg (5 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 115 V 50/60 Hz
- Special Features - Special
- System Labels & Instruction Manuals - French
100+ In Stock
$920.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Separate H2 Purity & Purge Gas Displays
- Hydrogen Purity Range - 100 % to 85 % (Does Not Conform to ATEX Directive)
- GAs Analysis Panel - None
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 115 V 50/60 Hz
- Special Features - None
- System Labels & Instruction Manuals - German
100+ In Stock
$959.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Single hydrogen Purity Display
- Hydrogen Purity Range - 100 % to 80 % (Does Not Conform to ATEX Directive)
- Purge Gas - None
- GAs Analysis Panel - High Pressure for Closed Loop 10 Barg (145 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 230 V 50/60 Hz
- Special Features - None
- System Labels & Instruction Manuals - French
100+ In Stock
$1,073.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Separate H2 Purity & Purge Gas Displays
- Hydrogen Purity Range - 100 % to 85 % (Does Not Conform to ATEX Directive)
- Purge Gas - Nitrogen
- GAs Analysis Panel - Low Pressure & Flame Traps for Vent to Atmosphere 0.35 Barg (5 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 230 V 50/60 Hz
- Special Features - Special
- System Labels & Instruction Manuals - Polish
100+ In Stock
$1,358.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Single hydrogen Purity Display
- Hydrogen Purity Range - 80/85 % to 100 %
- Purge Gas - CO2
- GAs Analysis Panel - None
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 230 V 50/60 Hz
- Special Features - Special
- System Labels & Instruction Manuals - French
100+ In Stock
$1,495.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Dual 3-Range Displays (H2 Purity & 2 x Purge Gas)
- Hydrogen Purity Range - 100 % to 80 % (Does Not Conform to ATEX Directive)
- Purge Gas - CO2
- GAs Analysis Panel - Low Pressure & Flame Traps for Vent to Atmosphere 0.35 Barg (5 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 230 V 50/60 Hz
- Special Features - Special
- System Labels & Instruction Manuals - English
100+ In Stock
$1,821.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Separate H2 Purity & Purge Gas Displays
- Hydrogen Purity Range - 100 % to 80 % (Does Not Conform to ATEX Directive)
- Purge Gas - Argon
- GAs Analysis Panel - High Pressure for Closed Loop 10 Barg (145 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 230 V 50/60 Hz
- Special Features - Special
- System Labels & Instruction Manuals - English
100+ In Stock
$1,895.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Single hydrogen Purity Display
- Hydrogen Purity Range - 100 % to 85 % (Does Not Conform to ATEX Directive)
- Purge Gas - Argon
- GAs Analysis Panel - Low Pressure & Flame Traps for Vent to Atmosphere 0.35 Barg (5 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 115 V 50/60 Hz
- Special Features - Special
- System Labels & Instruction Manuals - French
100+ In Stock
$1,927.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Single 3-Range (H2 Purity & 2 x Purge Gas)
- Hydrogen Purity Range - 100 % to 80 % (Does Not Conform to ATEX Directive)
- Purge Gas - Argon
- GAs Analysis Panel - High Pressure for Closed Loop 10 Barg (145 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 230 V 50/60 Hz
- Special Features - Special
- System Labels & Instruction Manuals - German
100+ In Stock
$1,928.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Separate H2 Purity & Purge Gas Displays
- Hydrogen Purity Range - 100 % to 80 % (Does Not Conform to ATEX Directive)
- GAs Analysis Panel - None
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 230 V 50/60 Hz
- Special Features - Special
- System Labels & Instruction Manuals - German
100+ In Stock
$1,967.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Single hydrogen Purity Display
- Hydrogen Purity Range - 100 % to 80 % (Does Not Conform to ATEX Directive)
- Purge Gas - None
- GAs Analysis Panel - None
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - None
- Special Features - Special
- System Labels & Instruction Manuals - French
100+ In Stock
$2,038.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Separate H2 Purity & Purge Gas Displays
- Hydrogen Purity Range - 100 % to 85 % (Does Not Conform to ATEX Directive)
- Purge Gas - CO2
- GAs Analysis Panel - None
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 230 V 50/60 Hz
- Special Features - Special
- System Labels & Instruction Manuals - English
100+ In Stock
$2,076.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Single hydrogen Purity Display
- Hydrogen Purity Range - 100 % to 80 % (Does Not Conform to ATEX Directive)
- GAs Analysis Panel - None
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 230 V 50/60 Hz
- Special Features - Special
- System Labels & Instruction Manuals - Polish
100+ In Stock
$2,267.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Dual 3-Range Displays (H2 Purity & 2 x Purge Gas)
- Hydrogen Purity Range - 100 % to 80 % (Does Not Conform to ATEX Directive)
- GAs Analysis Panel - None
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 115 V 50/60 Hz
- Special Features - None
- System Labels & Instruction Manuals - German
100+ In Stock
$2,315.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Separate H2 Purity & Purge Gas Displays
- Hydrogen Purity Range - 80/85 % to 100 %
- Purge Gas - Nitrogen
- GAs Analysis Panel - None
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 230 V 50/60 Hz
- Special Features - None
- System Labels & Instruction Manuals - German
100+ In Stock
$2,507.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Single hydrogen Purity Display
- Hydrogen Purity Range - 100 % to 80 % (Does Not Conform to ATEX Directive)
- Purge Gas - CO2
- GAs Analysis Panel - Low Pressure & Flame Traps for Vent to Atmosphere 0.35 Barg (5 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - None
- Special Features - None
- System Labels & Instruction Manuals - English
100+ In Stock
$113.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Dual 3-Range Displays (H2 Purity & 2 x Purge Gas)
- Hydrogen Purity Range - 100 % to 80 % (Does Not Conform to ATEX Directive)
- Purge Gas - Argon
- GAs Analysis Panel - None
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - None
- Special Features - Special
- System Labels & Instruction Manuals - German
100+ In Stock
$159.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Dual 3-Range Displays (H2 Purity & 2 x Purge Gas)
- Hydrogen Purity Range - 100 % to 85 % (Does Not Conform to ATEX Directive)
- Purge Gas - CO2
- GAs Analysis Panel - Low Pressure & Flame Traps for Vent to Atmosphere 0.35 Barg (5 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 230 V 50/60 Hz
- Special Features - Special
- System Labels & Instruction Manuals - French
100+ In Stock
$325.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Dual 3-Range Displays (H2 Purity & 2 x Purge Gas)
- Hydrogen Purity Range - 100 % to 85 % (Does Not Conform to ATEX Directive)
- GAs Analysis Panel - None
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - None
- Special Features - None
- System Labels & Instruction Manuals - Polish
100+ In Stock
$369.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Dual 3-Range Displays (H2 Purity & 2 x Purge Gas)
- Hydrogen Purity Range - 80/85 % to 100 %
- Purge Gas - Argon
- GAs Analysis Panel - None
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - None
- Special Features - Special
- System Labels & Instruction Manuals - English
100+ In Stock
$553.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Single hydrogen Purity Display
- Hydrogen Purity Range - 100 % to 85 % (Does Not Conform to ATEX Directive)
- Purge Gas - Argon
- GAs Analysis Panel - High Pressure for Closed Loop 10 Barg (145 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 230 V 50/60 Hz
- Special Features - None
- System Labels & Instruction Manuals - Polish
100+ In Stock
$557.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Single 3-Range (H2 Purity & 2 x Purge Gas)
- Hydrogen Purity Range - 80/85 % to 100 %
- Purge Gas - CO2
- GAs Analysis Panel - Low Pressure & Flame Traps for Vent to Atmosphere 0.35 Barg (5 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - None
- Special Features - Special
- System Labels & Instruction Manuals - French
100+ In Stock
$627.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Single hydrogen Purity Display
- Hydrogen Purity Range - 100 % to 85 % (Does Not Conform to ATEX Directive)
- Purge Gas - None
- GAs Analysis Panel - None
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 230 V 50/60 Hz
- Special Features - None
- System Labels & Instruction Manuals - English
100+ In Stock
$674.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Separate H2 Purity & Purge Gas Displays
- Hydrogen Purity Range - 80/85 % to 100 %
- Purge Gas - Nitrogen
- GAs Analysis Panel - None
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 115 V 50/60 Hz
- Special Features - Special
- System Labels & Instruction Manuals - French
100+ In Stock
$927.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Single hydrogen Purity Display
- Hydrogen Purity Range - 100 % to 85 % (Does Not Conform to ATEX Directive)
- GAs Analysis Panel - High Pressure for Closed Loop 10 Barg (145 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 230 V 50/60 Hz
- Special Features - Special
- System Labels & Instruction Manuals - Polish
100+ In Stock
$942.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Separate H2 Purity & Purge Gas Displays
- Hydrogen Purity Range - 100 % to 80 % (Does Not Conform to ATEX Directive)
- Purge Gas - Nitrogen
- GAs Analysis Panel - High Pressure for Closed Loop 10 Barg (145 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 230 V 50/60 Hz
- Special Features - None
- System Labels & Instruction Manuals - English
100+ In Stock
$1,182.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Separate H2 Purity & Purge Gas Displays
- Hydrogen Purity Range - 100 % to 80 % (Does Not Conform to ATEX Directive)
- GAs Analysis Panel - High Pressure for Closed Loop 10 Barg (145 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 230 V 50/60 Hz
- Special Features - Special
- System Labels & Instruction Manuals - French
100+ In Stock
$1,190.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Single hydrogen Purity Display
- Hydrogen Purity Range - 100 % to 85 % (Does Not Conform to ATEX Directive)
- Purge Gas - Argon
- GAs Analysis Panel - Low Pressure & Flame Traps for Vent to Atmosphere 0.35 Barg (5 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - None
- Special Features - None
- System Labels & Instruction Manuals - French
100+ In Stock
$1,284.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Dual 3-Range Displays (H2 Purity & 2 x Purge Gas)
- Hydrogen Purity Range - 100 % to 80 % (Does Not Conform to ATEX Directive)
- Purge Gas - CO2
- GAs Analysis Panel - None
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 230 V 50/60 Hz
- Special Features - None
- System Labels & Instruction Manuals - Polish
100+ In Stock
$1,359.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Single 3-Range (H2 Purity & 2 x Purge Gas)
- Hydrogen Purity Range - 100 % to 80 % (Does Not Conform to ATEX Directive)
- Purge Gas - Argon
- GAs Analysis Panel - Low Pressure & Flame Traps for Vent to Atmosphere 0.35 Barg (5 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - None
- Special Features - Special
- System Labels & Instruction Manuals - German
100+ In Stock
$1,369.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Single hydrogen Purity Display
- Hydrogen Purity Range - 100 % to 80 % (Does Not Conform to ATEX Directive)
- Purge Gas - CO2
- GAs Analysis Panel - High Pressure for Closed Loop 10 Barg (145 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 230 V 50/60 Hz
- Special Features - Special
- System Labels & Instruction Manuals - English
100+ In Stock
$1,672.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Single 3-Range (H2 Purity & 2 x Purge Gas)
- Hydrogen Purity Range - 80/85 % to 100 %
- Purge Gas - CO2
- GAs Analysis Panel - None
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - None
- Special Features - None
- System Labels & Instruction Manuals - French
100+ In Stock
$1,692.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Single 3-Range (H2 Purity & 2 x Purge Gas)
- Hydrogen Purity Range - 80/85 % to 100 %
- Purge Gas - Argon
- GAs Analysis Panel - None
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - None
- Special Features - None
- System Labels & Instruction Manuals - German
100+ In Stock
$1,937.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Single 3-Range (H2 Purity & 2 x Purge Gas)
- Hydrogen Purity Range - 100 % to 85 % (Does Not Conform to ATEX Directive)
- Purge Gas - Argon
- GAs Analysis Panel - High Pressure for Closed Loop 10 Barg (145 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - 115 V 50/60 Hz
- Special Features - None
- System Labels & Instruction Manuals - Polish
100+ In Stock
$1,979.00CAD
Does not ship to Ohio, United States
- Display Monitor Unit - Single 3-Range (H2 Purity & 2 x Purge Gas)
- Hydrogen Purity Range - 100 % to 85 % (Does Not Conform to ATEX Directive)
- GAs Analysis Panel - Low Pressure & Flame Traps for Vent to Atmosphere 0.35 Barg (5 psi) Max.
- Cubicle - Without Cubicle
- Gas Sample Flow Alarm - Not Fitted
- Katharometer Power Supply - None
- Special Features - Special
- System Labels & Instruction Manuals - French
100+ In Stock
$2,049.00CAD
Does not ship to Ohio, United States
Specifications
Brand
Certifications & Approvals
- ATEX
- CENELEC
- BASEEFA
Accuracy
- ± 0.25 % of scale Span
Ambient Temperature
- 6553 Gas Monitor: 0° to 40° C (32° to 104° F)
- 4234 Power Supply unit: -20° to 55° C (-4° to 131° F)
Power Supply
- 6553 Gas Monitor: 110/120 Vac or 200/220/240 Vac, 50/60 Hz
- 4234 Power Supply unit: 115 Vac or 230 Vac 50/60 Hz
Power Consumption
- 6553 Gas Monitor: 30 VA Approximately
- 4234 Power Supply unit: 30 W Max.
Humidity
- Sheltered interior, 0 to 90 % Relative Humidity
Operating Range
- 85 to 100 % H₂
- 0 to 100 % hydrogen in purge Gas
- 0 to 100 % Air in purge Gas