MBS 3200/MBS 3250 Pressure Transmitter
Brand: DanfossThe compact high temperature pressure transmitter MBS 3200 is designed for use in hydraulic and almost all industrial applications, and offers a reliable pressure measurement, even under harsh environmental conditions.
MBS 3250 with integrated pulse-snubber is designed for use in hydraulic applications with severe medium influences like cavitation, liquid hammer or pressure peaks and offers a reliable pressure measurement, even under harsh environmental conditions.
The flexible pressure transmitter programme covers different output signals, absolute or gauge (relative) versions, measuring ranges from 0-1 to 0-600 bar and a wide range of pressure and electrical connections.
A robust design, an excellent vibration stability and a high degree of EMC / EMI protection equip the pressure transmitter to meet the most stringent industrial requirements.
Specifications
Brand
Accuracy
- ≤ ± 0.5 % of Full Scale - Typical Includes Non-Linearity, Hysteresis & Repeatability
- ≤ ± 1 % of Full Scale, Max.
Ambient Temperature Range
- -40° to 125° C (-40° to 257° F)
Applications
- Hydraulic Applications
- Industrial Environments
Approvals & Certifications
- ATEX Zone 2 II 3 G Ex NA IIA T3 Gc -20° < Ta < 85° C
- CE
- EMC EN 61000-6-3 (Emission), EN 61000-6-2 (Immunity)
BSP Connection
- G 1/2” A (EN 837) - for Model MBS 3200
- G 1/4” A (EN 837)
Burst Pressure
- 6 x Full Scale [psi: 29,010 (MPa: 200, bar: 2,000) - Max.
Cable Length
- 6.56 feet (2 metres)
Cable Material
- Polyethylene (PE) - Shrinkage Tubing
- Polyolefin
Compensated Temperature
- 0° to 100° C (32° to 212° F)
Consumption
- ≤ 5 mA - Current Consumption
- ≤ 8 mA - Current Consumption
Current
- 28 mA Typical - Current Limitation
Electrical Connectors
- 2-Wire
- AMP Econoseal, J Series, Male
- AMP Superseal 1.5 Series (Male)
- M12 x 1 Plug 4-Pin
- PG9
- Screened Cable
Electrical Protection
- Polarity
- Short Circuit
Enclosure, Body Material
- 316L Stainless Steel
Environmental Protection
- IP65
- IP67
Gasket Material
- NBR
- Viton
Hysteresis
- ≤ ± 0.1 % of Full Scale
Insulation Resistance
- > 100 megaohms at 100 Vdc
Load Resistance
- ≥ 10 kiloohms - Load Connected to 0 V
- ≥ 15 kiloohms - Load Connected to 0 V
Materials of Construction
- Plug: Glass-Filled Polyamid
- Plug: Nickel-Plated Brass
Non-Linearity
- ≤ ± 0.2 % of Full Scale - BFSL (Conformity)
NPT Connection
- 1/2”-14 Male NPT
- 1/4”-18 Male NPT
O-Ring Material
- Viton
Output
- Nominal Output Signal (Short-Circuit Protected): 0-10 Vdc
- Nominal Output Signal (Short-Circuit Protected): 0-5 Vdc
- Nominal Output Signal (Short-Circuit Protected): 1-10 V
- Nominal Output Signal (Short-Circuit Protected): 1-5 Vdc
- Nominal Output Signal (Short-Circuit Protected): 1-6 Vdc
- Nominal Output Signal (Short-Circuit Protected): 4-20 mA
Output Impedence
- ≥ 25 kiloohms
Overpressure & Static Pressure Limits
- 6 x Full Scale [psi: 21,760 (kPa: 150,000, bar: 1,500) - Max.
Plug Material
- PBT
Pressure Cycles
- > 10 Million
Pressure Range
- bar: 0 to 600
- kPa: 0 to 60,000
- psi: 0 to 8,700
Pressure Type
- Absolute
- Gauge (Relative)
Repeatability
- ≤ ± 0.1 % of Full Scale
Response Time
- < 35 milliseconds - Air & Gases (MBS 3250)
- < 4 milliseconds - Liquids with Viscosity < 100 cSt
Shock
- 1 metre Free Fall as Per IEC 60068-2-32
- 500 G, 1 millisecond as Per IEC 60068-2-27
Storage Temperature
- -50° to 125° C (-58° to 257° F)
Supply Voltage
- ≤ ± 0.1 % of Full Scale/10 V - Supply Voltage Dependency
- 9-32 Vdc - Polarity Protected
Temperature Range
- -10° to 85° C (14° to 185° F) - ATEX Zone 2 Sensor
- -40° to 125° C (-40° to 257° F) - Normal Sensor
Thermal Drift
- ≤ ± 1 % of Full Scale - Thermal Error Band (Compensated Temperature Range)
Torque
- 30 to 35 Nm (265 to 310 In/Lbs)
Vibration
- Random Vibration: 7.5 G RMS, 5 to 1,000 Hz as Per IEC 60068-2-64
- Sinusoidal Vibration: 15.9 mm-pp, 5 to 25 Hz as Per IEC 60068-2-6
- Sinusoidal Vibration: 20 G, 25 to 2,000 Hz as Per IEC 60068-2-6
Wetted Materials
- 316L Stainless Steel
- Hydraulic Applications