EMP 2 Pressure Transmitter

Brand: Danfoss

The high accuracy pressure transmitter EMP 2 is designed for monitoring and control in marine and industial applications and offers a reliable pressure measurement, even under harsh environmental conditions.

The flexible pressure transmitter programme covers absolute or gauge (relative) versions with zero and span adjustment with a 4-20 mA output signal. It has all the necessary marine approvals.

Special versions with integrated pulse-snubber available, designed for use in hydraulic applications with severe medium influences like cavitation, liquid hammer or pressure peaks.
Features
  • For use in Zone 2 explosive atmosphere

Specifications

Brand

Accuracy

  • < 0.3 % of Full Scale
  • < 2.3 % of Full Scale - in Vacuum (Below bar: 0)

Applications

  • Hydraulic Applications

Approvals & Certifications

  • EN 60079-15
  • EN 60770
  • EN 61000-6-2 - Noise-Immunity
  • EN 61000-6-3 - Noise-Emission
  • ABS
  • ATEX II 3 G Ex NA IIA T3 Gc -20° < Ta < 85° C
  • BV
  • CCS
  • CE
  • DNV
  • EN 837
  • GL
  • IEC
  • ISO 228
  • KRS
  • LRS
  • NKK
  • RINA
  • RMRS

BSP Connection

  • G 1/2” Male A
  • G 3/8” Male A

Burst Pressure

  • psi: 1,450 to 14,500 (kPa: 10,000 to 100,000, bar: 100 to 1,000) - Min.

Cable Entry

  • PG13.5 for Cable 5-14 mm Diameter

Enclosure, Body Material

  • Die Cast Aluminum - Enamelled Pressure (GD-AISI 12)

Environmental Protection

  • IP67

Load Resistance

  • Maximum

Media

  • Ammonia
  • Fuel
  • Gas
  • Lubricating Oil
  • Oil
  • Refrigerants
  • Water

Mounting

  • Bracket

Operating Pressure

  • psi: -14.5 to 3,626 (kPa: -100 to 25,000, bar: -1 to 250)

Operating Temperature

  • -10° to 70° C (14° to 158° F)

Output

  • 4-20 mA

Pressure Type

  • Gauge

Process Temperature

  • -40° to 100° C (-40° to 212° F)

Proof Pressure

  • psi: 72.52 to 5,439 (kPa: 500 to 37,500, bar: 5 to 375)

Shock

  • 500 G as Per IEC 60068-2-27 - Shock Stability

Span & Zero Adjustments

  • ± 5 % of Span, Max.
  • -5 to 20 % of Span, But, Max.

Span & Zero Effect

  • ≤ ± 0.06 % of Full Scale/°C - Thermal Zero Point Shift & Thermal Sensitivity (Span) Shift

Storage Temperature

  • -50° to 70° C (-58° to 158° F)

Supply Voltage

  • ≤ ± 0.1 % of Full Scale/10 V - Voltage Dependency
  • Maximum
  • Minimum 12 Vdc - between Terminals N & P

Temperature Range

  • -10° to 70° C (14° to 158° F) - Normal Sensor
  • -10° to 85° C (14° to 185° F) - ATEX Zone 2 Sensor

Time Constant

  • < 35 milliseconds - Air & Gas in Combination with Pulse Snubber
  • < 4 milliseconds - Liquids with Viscosity < 100 cSt

Vibration

  • 3-30 Hz Amplitude 1.13 mm & 30-300 Hz Acceleration 4 G as Per IEC 60068-2-6

  • Hydraulic applications

show more