EMP 2 Pressure Transmitter
Brand: DanfossThe high accuracy pressure transmitter EMP 2 is designed for monitoring and control in marine and industial applications and offers a reliable pressure measurement, even under harsh environmental conditions.
The flexible pressure transmitter programme covers absolute or gauge (relative) versions with zero and span adjustment with a 4-20 mA output signal. It has all the necessary marine approvals.
Special versions with integrated pulse-snubber available, designed for use in hydraulic applications with severe medium influences like cavitation, liquid hammer or pressure peaks.
Features- For use in Zone 2 explosive atmosphere
Specifications
Brand
Accuracy
- < 0.3 % of Full Scale
- < 2.3 % of Full Scale - in Vacuum (Below bar: 0)
Applications
- Hydraulic Applications
Approvals & Certifications
- EN 60079-15
- EN 60770
- EN 61000-6-2 - Noise-Immunity
- EN 61000-6-3 - Noise-Emission
- ABS
- ATEX II 3 G Ex NA IIA T3 Gc -20° < Ta < 85° C
- BV
- CCS
- CE
- DNV
- EN 837
- GL
- IEC
- ISO 228
- KRS
- LRS
- NKK
- RINA
- RMRS
BSP Connection
- G 1/2” Male A
- G 3/8” Male A
Burst Pressure
- psi: 1,450 to 14,500 (kPa: 10,000 to 100,000, bar: 100 to 1,000) - Min.
Cable Entry
- PG13.5 for Cable 5-14 mm Diameter
Enclosure, Body Material
- Die Cast Aluminum - Enamelled Pressure (GD-AISI 12)
Environmental Protection
- IP67
Load Resistance
- Maximum
Media
- Ammonia
- Fuel
- Gas
- Lubricating Oil
- Oil
- Refrigerants
- Water
Mounting
- Bracket
Operating Pressure
- psi: -14.5 to 3,626 (kPa: -100 to 25,000, bar: -1 to 250)
Operating Temperature
- -10° to 70° C (14° to 158° F)
Output
- 4-20 mA
Pressure Type
- Gauge
Process Temperature
- -40° to 100° C (-40° to 212° F)
Proof Pressure
- psi: 72.52 to 5,439 (kPa: 500 to 37,500, bar: 5 to 375)
Shock
- 500 G as Per IEC 60068-2-27 - Shock Stability
Span & Zero Adjustments
- ± 5 % of Span, Max.
- -5 to 20 % of Span, But, Max.
Span & Zero Effect
- ≤ ± 0.06 % of Full Scale/°C - Thermal Zero Point Shift & Thermal Sensitivity (Span) Shift
Storage Temperature
- -50° to 70° C (-58° to 158° F)
Supply Voltage
- ≤ ± 0.1 % of Full Scale/10 V - Voltage Dependency
- Maximum
- Minimum 12 Vdc - between Terminals N & P
Temperature Range
- -10° to 70° C (14° to 158° F) - Normal Sensor
- -10° to 85° C (14° to 185° F) - ATEX Zone 2 Sensor
Time Constant
- < 35 milliseconds - Air & Gas in Combination with Pulse Snubber
- < 4 milliseconds - Liquids with Viscosity < 100 cSt
Vibration
- 3-30 Hz Amplitude 1.13 mm & 30-300 Hz Acceleration 4 G as Per IEC 60068-2-6
- Hydraulic applications