AX455 USP Dual Channel Transmitter for 2-Electrode Conductivity Cell

Brand: ABB Group

The AX455 conductivity transmitter is designed for use with two of ABB’s 2-electrode conductivity cells for complete compliance with USP .

The cost-saving, dual channel transmitter measures conductivity with exceptional accuracy and performance.

It incorporates the latest technology to provide a highly reliable, flexible, feature-packed device that satisfies the needs of the Global pharmaceutical industries.

The unit provides an automatic Stage 1 alarm for USP monograph 645 and comes complete with all requisite documentation.
Features
  • Cost effective
    • select one or two conductivity inputs or combine conductivity and pH/Redox (ORP) in one analyzer
  • Reduced installation cost
    • easy access terminations; reduced panel space
  • High functionality at minimum cost
    • conductivity, resistivity, difference, ratio, % passage, % rejection and inferred pH calculations
  • Expanded monitoring and control
    • add-on option board provides a total of five alarm relays and four current outputs
    • service logbook providing historical data
  • Energy saving
    • high visibility, backlit display with auto switch-off function
  • Reduced yearly maintenance costs
    • 30 Vdc option negates the need for costly safety tests

72 models matching criteria
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, North American
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - Italian
  • Wall-mount IP65, North American - Pipe-Mount
100+ In Stock
$1,578.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Panel-Mount, Universal
  • Advanced Functions & Communications - Profibus DP, Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - Italian
  • Panel-mount, Universal - Panel-Mount
100+ In Stock
$1,129.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Panel-Mount, Universal
  • Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 12 to 30 Vdc
  • Manual - Italian
  • Panel-mount, Universal - Panel-Mount
100+ In Stock
$427.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 12 to 30 Vdc
  • Manual - French
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
100+ In Stock
$1,275.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, North American
  • Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - French
  • Wall-mount IP65, North American - Pipe-Mount
100+ In Stock
$2,537.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, North American
  • Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - French
  • Wall-mount IP65, North American - Wall-Mount
100+ In Stock
$355.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, North American
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 12 to 30 Vdc
  • Manual - French
  • Wall-mount IP65, North American - Wall-Mount
100+ In Stock
$1,676.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, North American
  • Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - Italian
  • Wall-mount IP65, North American - Pipe-Mount
100+ In Stock
$2,549.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, North American
  • Advanced Functions & Communications - Profibus DP, Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 12 to 30 Vdc
  • Manual - English
  • Wall-mount IP65, North American - Wall-Mount
100+ In Stock
$288.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, North American
  • Advanced Functions & Communications - Profibus DP, Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - Italian
  • Wall-mount IP65, North American - Wall-Mount
100+ In Stock
$2,147.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, North American
  • Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - English
  • Wall-mount IP65, North American - Pipe-Mount
100+ In Stock
$277.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Profibus DP, Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 12 to 30 Vdc
  • Manual - English
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
100+ In Stock
$1,116.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, North American
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - French
  • Wall-mount IP65, North American - Pipe-Mount
100+ In Stock
$2,211.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, North American
  • Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 12 to 30 Vdc
  • Manual - French
  • Wall-mount IP65, North American - Wall-Mount
100+ In Stock
$1,503.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Panel-Mount, Universal
  • Advanced Functions & Communications - Profibus DP, Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 12 to 30 Vdc
  • Manual - English
  • Panel-mount, Universal - Panel-Mount
50+ In Stock
$1,682.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Panel-Mount, Universal
  • Advanced Functions & Communications - Profibus DP, Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 12 to 30 Vdc
  • Manual - French
  • Panel-mount, Universal - Panel-Mount
50+ In Stock
$955.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, North American
  • Advanced Functions & Communications - Profibus DP, Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - English
  • Wall-mount IP65, North American - Wall-Mount
50+ In Stock
$2,420.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, North American
  • Advanced Functions & Communications - Profibus DP, Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - French
  • Wall-mount IP65, North American - Pipe-Mount
50+ In Stock
$450.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 12 to 30 Vdc
  • Manual - French
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
50+ In Stock
$547.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Profibus DP, Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - Italian
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
50+ In Stock
$776.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Panel-Mount, Universal
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - Italian
  • Panel-mount, Universal - Panel-Mount
50+ In Stock
$1,580.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Panel-Mount, Universal
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - French
  • Panel-mount, Universal - Panel-Mount
50+ In Stock
$525.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Profibus DP, Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - French
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
50+ In Stock
$504.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Panel-Mount, Universal
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 12 to 30 Vdc
  • Manual - English
  • Panel-mount, Universal - Panel-Mount
50+ In Stock
$1,399.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Panel-Mount, Universal
  • Advanced Functions & Communications - Profibus DP, Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - French
  • Panel-mount, Universal - Panel-Mount
50+ In Stock
$1,039.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, North American
  • Advanced Functions & Communications - Profibus DP, Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 12 to 30 Vdc
  • Manual - Italian
  • Wall-mount IP65, North American - Wall-Mount
50+ In Stock
$256.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - French
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
50+ In Stock
$856.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, North American
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 12 to 30 Vdc
  • Manual - Italian
  • Wall-mount IP65, North American - Pipe-Mount
50+ In Stock
$2,409.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 12 to 30 Vdc
  • Manual - English
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
50+ In Stock
$1,205.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, North American
  • Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 12 to 30 Vdc
  • Manual - Italian
  • Wall-mount IP65, North American - Pipe-Mount
50+ In Stock
$1,206.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, North American
  • Advanced Functions & Communications - Profibus DP, Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - French
  • Wall-mount IP65, North American - Wall-Mount
50+ In Stock
$2,555.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Profibus DP, Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 12 to 30 Vdc
  • Manual - Italian
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
50+ In Stock
$1,561.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, North American
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - English
  • Wall-mount IP65, North American - Pipe-Mount
50+ In Stock
$301.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - Italian
  • Wall-Mount IP65, General - Pipe-Mount
50+ In Stock
$1,182.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, North American
  • Advanced Functions & Communications - Profibus DP, Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 12 to 30 Vdc
  • Manual - French
  • Wall-mount IP65, North American - Pipe-Mount
50+ In Stock
$1,155.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, North American
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 12 to 30 Vdc
  • Manual - English
  • Wall-mount IP65, North American - Wall-Mount
50+ In Stock
$504.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, North American
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - Italian
  • Wall-mount IP65, North American - Wall-Mount
50+ In Stock
$454.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Panel-Mount, Universal
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 12 to 30 Vdc
  • Manual - French
  • Panel-mount, Universal - Panel-Mount
50+ In Stock
$673.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, North American
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 12 to 30 Vdc
  • Manual - Italian
  • Wall-mount IP65, North American - Wall-Mount
50+ In Stock
$693.00CAD
Does not ship to Massachusetts, United States
  • First Process Variable (PV1) - Conductivity USP for 2-Electrode Sensors
  • Second Process Variable (PV2) - Conductivity USP for 2-Electrode Sensors
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Profibus DP, Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 12 to 30 Vdc
  • Manual - French
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
50+ In Stock
$912.00CAD
Does not ship to Massachusetts, United States

Specifications

Brand

Mounting

  • Wall Mounting
  • Pipe Mounting
  • Panel Mounting

Environmental Protection

  • NEMA 4X
  • IP65

Power Supply

  • 12-30 Vdc
  • 85-265 Vac

Power Consumption

  • 10 W

Certifications & Approvals

  • UL
  • CE
  • EMC

Communication

  • PROFIBUS DP

Range

  • Programmable 0 to 0.5 to 0 to 10,000 µS cm-1

Span

  • (10 to 10,000) x Cell Constant

Accuracy

  • > ± 1 % of Reading (10,000 µS cm-1)
  • > ± 0.01 % of Span (0 to 100 µS cm-1)

Operating Temperature

  • -20° to 55° C (-4° to 131° F)
  • Conductivity: -10° to 200° C (14° to 392° F)

Storage Temperature

  • -25° to 75° C (13° to 167° F)

Temperature Compensation

  • Conductivity: -10° to 200° C (14° to 392° F)

Display

  • Dual 5-digit, 7-segment backlit LCD

Temperature Sensor

  • Programmable Pt100 or Pt1000

Humidity

  • Up to 95 % Relative Humidity Non-Condensing

  • Water and Waste Water Treatment
  • Power, Pure Water
  • Semiconductors
  • Chemicals
  • Pharmaceuticals
  • Pulp & Paper
show more