LM80 Intermediate Range Laser Level Transmitter

Brand: ABB Group

Based on pulsed laser technology, the LM80 embodies speed and accuracy in a single, easy to use and install product. 

Whether measuring a few meters into the confined space of a crusher, or to the bottom of the tallest silo, the LM80 with its laser pointer and long range is the plug-and-play solution to level measurement.

The LM80 features advanced timing and sophisticated signal processing for pinpoint accuracy at up to 100 m (330 ft.) for level applications and up to 150 m (500 ft.) for positioning applications.
Features
  • Maintenance free, non-contact continuous level sensor
  • Range up to 100 m (330 ft) for level applications
  • Range up to 150 m (500 ft) for positioning applications
  • Easy and intuitive setup
  • No calibration required
  • Continuous level monitoring for granular solid materials and opaque liquids
  • Measures solids and opaque liquids at any angle
  • Last Pulse Detection for Measurement with Light and Moderate Dust
  • Built-in laser pointer for accurate alignment in narrow or tall vessels
  • Auto-ranging to measure all levels
  • Available non condensing heated optics prevent condensation issues
  • No Beam Divergence = No False Echoes
  • Rugged and Robust Aluminum Enclosure
  • CSA, ATEX and IECEx potentially explosive atmosphere ratings

Specifications

Brand

Range

  • 0.5 m (1.5 ft) to 30 m (100 ft) - dark colored surfaces
  • 0.5 m (1.5 ft) to 100 m (150 ft) - light colored surfaces
  • 0.5 m (1.5 ft) to 150 m (500 ft) - reflective targets in positioning applications

Resolution

  • ± 10 mm (0.4 in)

Accuracy

  • ± 30 mm (1.2 in)

Update Rate

  • 3 Readings per second (Max.), 1 Reading per minute (Min.)

Operating Temperature

  • -40° C to +60° C (-40° F to +140° F)
  • -40° C to +45° C (-40° F to +113° F) with Non-Condensing option (heated lens option (AC and SC))

Survival Temperature

  • -40° C to +80° C / -40° F to +176° F

Pressure

  • 1 bar

Analog

  • 4-20 mA, NAMUR compliant Non-Isolated and self Powered

Digital (Relay)

  • 2 SPST Relays: 0.5 A at 120 Vac, 0.25 A at 250 Vac, 1 A at 24 Vdc, 0.5 A at 60 Vdc

Communication

  • Standard Male DB9 Connector - RS-232 for testing, troubleshooting and configuration 19200 baud, 8 data bits, 1 stop bit, no Parity, no flow Control

Voltage

  • 24 Vdc typical (18 to 32 Vdc)

Current

  • 0.4 A peak, 0.2 A Continuous
  • 0.52 A peak, 0.32 A Continuous with Non-Condensing optics

Base Plate Diameter

  • Flange - 140 mm (5.51 in)
  • Tri-Clover - 120 mm (4.72 in)

Length

  • Flange - 172 mm (6.77 in)
  • Tri-Clover - 166 mm (6.54 in)

Weight

  • 316 Stainless Steel Enclosure - 4.2 kg (9.26 lbs)
  • Aluminum Enclosure - 1.6 kg (3.53 lbs)
  • Aluminum Enclosure with Tri-Clover - 2.2 kg (4.85 lbs)

Enclosure Material

  • Powder-Coated Aluminum Standard, 316 Stainless Steel option

O-Ring Seal Material

  • Buna-N (Nitrile Rubber)

Mounting / Process Connection

  • Tri-Clover - 316 Stainless Steel plate with Seal groove
  • Flange - 4 holes, 8.5 mm (0.33 in) diameter on 120 mm (4.72 in) diameter Circle

Total Optical Aperture

  • 90 mm (3 in)

Measuring Laser Lens Diameter

  • 25 mm (1 in)

Receiver Lens Diameter

  • 50 mm (1.97 in)

Lens Material

  • Acrylic

Lens Impact Resistance

  • Impact tested at 4 joule

Beam Divergence

  • < 0.3°

Beam Direction

  • 90° ± 1° from Mounting flange

Measuring Laser

  • 905 nm near infrared pulsed semiconductor laser
  • 12 mW Average Power output
  • 20 W peak Power output

Pointing Laser

  • 635 nm Red semiconductor laser
  • 3 mW Continuous

Measuring Laser Life Expectancy

  • 25 Years typical MTBF

Purge Air Flow

  • Must be oil free dry Air recommended flow between 0.5 and 4 L/minute Max. pressure 5.5 bar (80 psi)

Purge Fitting

  • 1/8 NPT

Enclosure Rating

  • IP66/NEMA 4X (Dust proof, can be washed down with High Pressure Hose)
show more