GAA610-M Advanced Emission Gas Monitoring System

Part Number: GAA610-M Brand: ABB Group

ABB Advanced Emission Gas Monitoring System for Marine Applications

Price
$2,009.00 CAD
Stock
50+ In Stock

The GAA610-M is a multi-component analyzer system continuously providing real-time data of relevant pollutants like SO2/CO2 ratio or NOx emissions. 

It proves compliance of vessels to low emission limits of emission control areas (ECA zones) and global limits. 

The measurement can be used to control the exhaust gas cleaning system on board, so called scrubber as well.

The GAA610-M is proven for use on board by all major classification societies and complies with Marpol Annex IV requirements and NOx Technical Code2008. 

Reducing maintenance hassles during ship operation has been the guiding principle for development. 

An increased uptime is provided with the GAA610-M by its robust and simple design as well as its innovative digital features allowing for tailored services according your needs.
Features
  • Guarantee compliance with latest IMO regulations
    • Certified system for emission monitoring in marine industry
    • Type approved by all major classification societies
  • Decrease maintenance hassle by increased system uptime
    • Simple system design suitable for challenging ambient conditions
    • Minimized maintenance tasks
    • Digitally enabled for smart services
    • ABB AbilityTM Remote Assistance process downtime

Specifications

Brand

Certifications & Approvals

  • DNV GL
  • ClassNK
  • Korean Register of Shipping (KR)
  • ABS Group
  • Bureau Veritas
  • Lloyd's Register

Operating Temperature

  • 5° to 55° C (41° to 131° F)

Environmental Protection

  • IP54

Measurement Range

  • CO (Option): 0 to 500 ppm
  • O₂ (Option): 0 to 25 Vol %
  • SO₂: 0 to 250 ppm, 0 to 500 ppm
  • CO₂: 0 to 20 Vol %

Temperature Range

  • Sample Gas inlet: Max. 500° C (932° F)

Pressure Range

  • Instrument Air inlet: 400 to 600 kPa (60 to 90 psig)
  • Sample Gas inlet: 850 to 1100 hPa (0.85 to 1.1 bar), (12.3 to 16 psi)

Air Consumption

  • < 0.2 Nm³/day

Linearity

  • < 2 % of Reading or Max. 0.3 % of Span whichever is greater

Precision

  • For Measuring Ranges > 100 ppm: 100 ppm: < ± 1 % of Span
  • For Measuring Ranges < 100 ppm: < ± 2 % of Span

Drift

  • Span Drift SO₂, CO₂: ≤ 2 % of measured value per week
  • Zero Drift SO₂, CO₂: ≤ 2 % of Span per week

Warm-Up Time

  • 30 minutes (with thermostat)

Material of Construction

  • Painted Electro Galvanized (EG) Steel

Mounting

  • Wall Mounted / Rack Mounted

Power Supply

  • 230 Vac, ± 10 %, 50 to 60 Hz, ± 3 Hz

Power Consumption

  • Heated sample gas line: Approximately 90 W/m
  • Sampling probe: 300 W
  • Air conditioner: 1,600 W
  • System cabinet: 500 W

Communication

  • Modbus
  • RS-232 Interface
  • Ethernet

Emission monitoring for clean air on oceans brings maritime air pollution control closely in line with shore-based power plants, cement works and oil refineries, where continuous emissions monitoring systems (CEMS) have been used for decades.