ACS880-307LC Liquid-Cooled Diode Supply Unit

Brand: ABB Group

Our liquid-cooled diode supply units take compactness to a new level.

The unit is designed to be compact and light, with integrated AC-chokes, current measurements and inbuilt DC-charging functionality.

The units, which can be connected in parallel to achieve higher power, have half-controlled diode-thyristor supply unit.
Features
  • Available for single drives and multi drives
  • One core diode supply module, which can be connected in parallel for higher powers
  • Inbuilt AC-chokes
  • Half-controlled diode-thyristor supply unit
  • DC-charging capability
  • Internal current measurement
  • 6/12 pulse AC supplies are supported

1,728 models matching criteria
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 1060 A
  • EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
  • Output Filter - Common Mode Filter
  • Incoming Unit Apparatus - Earthing Switch
  • Safety Function - None (Not Required)
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$59.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 2000 A
  • EMC Filter - 2nd Environment, C3, Grounded (TN) & Ungrounded Network (IT)*
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Earthing Switch
  • Safety Function - Emergency Stop, Configurable Category 0 or 1 with STO & Safety Functions Module (FSO-12/-21)
  • Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$178.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 4000 A
  • EMC Filter - None (Not Required)
  • Output Filter - Common Mode Filter
  • Incoming Unit Apparatus - Air Circuit Breaker
  • Safety Function - Emergency Stop, Category 0 with STO, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$399.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 12-Pulse, DSU
  • Current Rating - 920 A
  • EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Earthing Switch
  • Safety Function - Emergency Stop, Category 1 with Opening the Main Contactor/Breaker, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$609.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 2000 A
  • EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
  • Output Filter - Common Mode Filter
  • Incoming Unit Apparatus - Air Circuit Breaker
  • Safety Function - Emergency Stop, Category 1 with STO, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$617.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 2000 A
  • EMC Filter - None (Not Required)
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Air Circuit Breaker
  • Safety Function - Emergency Stop, Category 1 with Opening the Main Contactor/Breaker, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$629.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 1470 A
  • EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
  • Output Filter - Common Mode Filter
  • Incoming Unit Apparatus - Air Circuit Breaker
  • Safety Function - Emergency Stop, Configurable Category 0 or 1 with STO & Safety Functions Module (FSO-12/-21)
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$640.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 1060 A
  • EMC Filter - 2nd Environment, C3, Grounded (TN) & Ungrounded Network (IT)*
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Air Circuit Breaker
  • Safety Function - Emergency Stop, Configurable Category 0 or 1 with STO & Safety Functions Module (FSO-12/-21)
  • Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$736.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 490 A
  • EMC Filter - None (Not Required)
  • Output Filter - Common Mode Filter
  • Incoming Unit Apparatus - Air Circuit Breaker
  • Safety Function - Emergency Stop, Category 0 with STO, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$757.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 780 A
  • EMC Filter - 2nd Environment, C3, Grounded (TN) & Ungrounded Network (IT)*
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Earthing Switch
  • Safety Function - Emergency Stop, Category 0 with STO, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$972.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 12-Pulse, DSU
  • Current Rating - 2940 A
  • EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
  • Output Filter - Common Mode Filter
  • Incoming Unit Apparatus - Air Circuit Breaker
  • Safety Function - Emergency Stop, Category 0 with Opening the Main Contactor/Breaker, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$1,017.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 1060 A
  • EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Earthing Switch
  • Safety Function - Emergency Stop, Configurable Category 0 or 1 with STO & Safety Functions Module (FSO-12/-21)
  • Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$1,335.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 12-Pulse, DSU
  • Current Rating - 2940 A
  • EMC Filter - 2nd Environment, C3, Grounded (TN) & Ungrounded Network (IT)*
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Air Circuit Breaker
  • Safety Function - Emergency Stop, Category 0 with STO, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$1,418.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 490 A
  • EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
  • Output Filter - Common Mode Filter
  • Incoming Unit Apparatus - Air Circuit Breaker
  • Safety Function - None (Not Required)
  • Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$1,725.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 12-Pulse, DSU
  • Current Rating - 2000 A
  • EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Air Circuit Breaker
  • Safety Function - Emergency Stop, Category 1 with Opening the Main Contactor/Breaker, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$1,833.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 12-Pulse, DSU
  • Current Rating - 2000 A
  • EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Earthing Switch
  • Safety Function - None (Not Required)
  • Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$1,841.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 4000 A
  • EMC Filter - None (Not Required)
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Earthing Switch
  • Safety Function - Emergency Stop, Category 1 with Opening the Main Contactor/Breaker, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$2,226.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 12-Pulse, DSU
  • Current Rating - 4000 A
  • EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Earthing Switch
  • Safety Function - Emergency Stop, Category 1 with Opening the Main Contactor/Breaker, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$2,292.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 1060 A
  • EMC Filter - 2nd Environment, C3, Grounded (TN) & Ungrounded Network (IT)*
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Earthing Switch
  • Safety Function - Emergency Stop, Configurable Category 0 or 1 with STO & Safety Functions Module (FSO-12/-21)
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$2,418.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 12-Pulse, DSU
  • Current Rating - 920 A
  • EMC Filter - None (Not Required)
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Earthing Switch
  • Safety Function - Emergency Stop, Category 0 with Opening the Main Contactor/Breaker, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$2,518.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 12-Pulse, DSU
  • Current Rating - 1470 A
  • EMC Filter - 2nd Environment, C3, Grounded (TN) & Ungrounded Network (IT)*
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Earthing Switch
  • Safety Function - Emergency Stop, Category 1 with Opening the Main Contactor/Breaker, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$777.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 490 A
  • EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Air Circuit Breaker
  • Safety Function - Emergency Stop, Category 0 with STO, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$1,461.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 3000 A
  • EMC Filter - 2nd Environment, C3, Grounded (TN) & Ungrounded Network (IT)*
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Earthing Switch
  • Safety Function - None (Not Required)
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$1,821.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 1060 A
  • EMC Filter - None (Not Required)
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Earthing Switch
  • Safety Function - Emergency Stop, Configurable Category 0 or 1 with STO & Safety Functions Module (FSO-12/-21)
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$1,992.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 2000 A
  • EMC Filter - None (Not Required)
  • Output Filter - Common Mode Filter
  • Incoming Unit Apparatus - Earthing Switch
  • Safety Function - Emergency Stop, Category 0 with STO, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$137.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 12-Pulse, DSU
  • Current Rating - 4000 A
  • EMC Filter - None (Not Required)
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Air Circuit Breaker
  • Safety Function - Emergency Stop, Category 0 with Opening the Main Contactor/Breaker, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$196.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 2000 A
  • EMC Filter - None (Not Required)
  • Output Filter - Common Mode Filter
  • Incoming Unit Apparatus - Earthing Switch
  • Safety Function - Emergency Stop, Configurable Category 0 or 1 with STO & Safety Functions Module (FSO-12/-21)
  • Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$202.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 1470 A
  • EMC Filter - None (Not Required)
  • Output Filter - Common Mode Filter
  • Incoming Unit Apparatus - Air Circuit Breaker
  • Safety Function - Emergency Stop, Category 1 with Opening the Main Contactor/Breaker, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$299.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 1060 A
  • EMC Filter - None (Not Required)
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Earthing Switch
  • Safety Function - Emergency Stop, Category 0 with STO, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$531.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 1060 A
  • EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
  • Output Filter - Common Mode Filter
  • Incoming Unit Apparatus - Air Circuit Breaker
  • Safety Function - None (Not Required)
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$727.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 1470 A
  • EMC Filter - None (Not Required)
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Earthing Switch
  • Safety Function - Emergency Stop, Category 1 with Opening the Main Contactor/Breaker, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$835.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 12-Pulse, DSU
  • Current Rating - 1470 A
  • EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
  • Output Filter - Common Mode Filter
  • Incoming Unit Apparatus - Earthing Switch
  • Safety Function - Emergency Stop, Category 1 with STO, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$873.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 4000 A
  • EMC Filter - 2nd Environment, C3, Grounded (TN) & Ungrounded Network (IT)*
  • Output Filter - Common Mode Filter
  • Incoming Unit Apparatus - Air Circuit Breaker
  • Safety Function - Emergency Stop, Configurable Category 0 or 1 with STO & Safety Functions Module (FSO-12/-21)
  • Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$1,039.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 4000 A
  • EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Earthing Switch
  • Safety Function - Emergency Stop, Category 1 with STO, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$1,188.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 12-Pulse, DSU
  • Current Rating - 2000 A
  • EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
  • Output Filter - Common Mode Filter
  • Incoming Unit Apparatus - Air Circuit Breaker
  • Safety Function - None (Not Required)
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$1,244.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 12-Pulse, DSU
  • Current Rating - 920 A
  • EMC Filter - 2nd Environment, C3, Grounded (TN) & Ungrounded Network (IT)*
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Air Circuit Breaker
  • Safety Function - Emergency Stop, Category 1 with Opening the Main Contactor/Breaker, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$1,265.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 12-Pulse, DSU
  • Current Rating - 2940 A
  • EMC Filter - 2nd Environment, C3, Grounded (TN) & Ungrounded Network (IT)*
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Earthing Switch
  • Safety Function - Emergency Stop, Configurable Category 0 or 1 with STO & Safety Functions Module (FSO-12/-21)
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$1,467.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 12-Pulse, DSU
  • Current Rating - 1470 A
  • EMC Filter - 2nd Environment, C3, Grounded (TN) & Ungrounded Network (IT)*
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Air Circuit Breaker
  • Safety Function - Emergency Stop, Category 0 with Opening the Main Contactor/Breaker, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$1,709.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 12-Pulse, DSU
  • Current Rating - 4000 A
  • EMC Filter - None (Not Required)
  • Output Filter - Du/dt Filters
  • Incoming Unit Apparatus - Earthing Switch
  • Safety Function - Emergency Stop, Configurable Category 0 or 1 with STO & Safety Functions Module (FSO-12/-21)
  • Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$1,819.00CAD
Does not ship to Washington, United States
  • Voltage - 690 V (Range 525-690 V)
  • Pulse - 6-Pulse, Half-Controlled Diode Bridge
  • Current Rating - 1470 A
  • EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
  • Output Filter - Common Mode Filter
  • Incoming Unit Apparatus - Earthing Switch
  • Safety Function - Emergency Stop, Category 1 with Opening the Main Contactor/Breaker, with Safety Relay
  • Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$1,850.00CAD
Does not ship to Washington, United States

Specifications

Brand

Voltage & Power Range

  • Mains: 3-Phase, UN3 380-415 V, +10 %/-10 %
  • Mains: 585 to 7,027 kVA
  • Motor: 3-Phase output Voltage 0 to UN3 /UN5 /UN7
  • Mains: 3-Phase, UN7 525-690 V, +10 %/-10 %

Frequency

  • Motor: 0 to ± 598 Hz
  • Mains: 50/60 Hz ± 5 %

Storage / Transport Temperature

  • -40° to 70° C

Operating Temperature

  • Liquid-Cooled: 45° to 55° C with Derating of 0.5 %/1° C
  • Liquid-Cooled: 0° to 45° C, No Frost Allowed

Motor Control

  • Direct torque Control (DTC)

Certifications & Approvals

  • cULus, CSA
  • RCM, EAC
  • TÜV
  • RoHS
  • LVD
  • ATEX
  • CE
  • EMC

Environmental Protection

  • IP54
  • IP42
  • IP22

Altitude

  • 0 to 1,000 m, without derating
  • 1,000 to 4,000 m, with derating of 1 %/100 m

Humidity

  • 5 % to 95 % Relative Humidity, no condensation
show more