ACS880-307LC Liquid-Cooled Diode Supply Unit
Brand: ABB GroupOur liquid-cooled diode supply units take compactness to a new level.
The unit is designed to be compact and light, with integrated AC-chokes, current measurements and inbuilt DC-charging functionality.
The units, which can be connected in parallel to achieve higher power, have half-controlled diode-thyristor supply unit.
Features- Available for single drives and multi drives
- One core diode supply module, which can be connected in parallel for higher powers
- Inbuilt AC-chokes
- Half-controlled diode-thyristor supply unit
- DC-charging capability
- Internal current measurement
- 6/12 pulse AC supplies are supported
Displaying prices & availability for Ohio, United States in CAD. Change location.
Featured
- Featured
- Quantity In Stock
- Price
- SKU / Model Number
Models matching criteria: 1,728
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 1060 A
- EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
- Output Filter - Common Mode Filter
- Incoming Unit Apparatus - Earthing Switch
- Safety Function - None (Not Required)
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$59.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 2000 A
- EMC Filter - 2nd Environment, C3, Grounded (TN) & Ungrounded Network (IT)*
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Earthing Switch
- Safety Function - Emergency Stop, Configurable Category 0 or 1 with STO & Safety Functions Module (FSO-12/-21)
- Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$178.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 4000 A
- EMC Filter - None (Not Required)
- Output Filter - Common Mode Filter
- Incoming Unit Apparatus - Air Circuit Breaker
- Safety Function - Emergency Stop, Category 0 with STO, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$399.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 12-Pulse, DSU
- Current Rating - 920 A
- EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Earthing Switch
- Safety Function - Emergency Stop, Category 1 with Opening the Main Contactor/Breaker, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$609.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 2000 A
- EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
- Output Filter - Common Mode Filter
- Incoming Unit Apparatus - Air Circuit Breaker
- Safety Function - Emergency Stop, Category 1 with STO, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$617.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 2000 A
- EMC Filter - None (Not Required)
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Air Circuit Breaker
- Safety Function - Emergency Stop, Category 1 with Opening the Main Contactor/Breaker, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$629.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 1470 A
- EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
- Output Filter - Common Mode Filter
- Incoming Unit Apparatus - Air Circuit Breaker
- Safety Function - Emergency Stop, Configurable Category 0 or 1 with STO & Safety Functions Module (FSO-12/-21)
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$640.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 1060 A
- EMC Filter - 2nd Environment, C3, Grounded (TN) & Ungrounded Network (IT)*
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Air Circuit Breaker
- Safety Function - Emergency Stop, Configurable Category 0 or 1 with STO & Safety Functions Module (FSO-12/-21)
- Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$736.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 490 A
- EMC Filter - None (Not Required)
- Output Filter - Common Mode Filter
- Incoming Unit Apparatus - Air Circuit Breaker
- Safety Function - Emergency Stop, Category 0 with STO, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$757.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 780 A
- EMC Filter - 2nd Environment, C3, Grounded (TN) & Ungrounded Network (IT)*
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Earthing Switch
- Safety Function - Emergency Stop, Category 0 with STO, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$972.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 12-Pulse, DSU
- Current Rating - 2940 A
- EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
- Output Filter - Common Mode Filter
- Incoming Unit Apparatus - Air Circuit Breaker
- Safety Function - Emergency Stop, Category 0 with Opening the Main Contactor/Breaker, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$1,017.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 1060 A
- EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Earthing Switch
- Safety Function - Emergency Stop, Configurable Category 0 or 1 with STO & Safety Functions Module (FSO-12/-21)
- Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$1,335.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 12-Pulse, DSU
- Current Rating - 2940 A
- EMC Filter - 2nd Environment, C3, Grounded (TN) & Ungrounded Network (IT)*
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Air Circuit Breaker
- Safety Function - Emergency Stop, Category 0 with STO, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$1,418.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 490 A
- EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
- Output Filter - Common Mode Filter
- Incoming Unit Apparatus - Air Circuit Breaker
- Safety Function - None (Not Required)
- Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$1,725.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 12-Pulse, DSU
- Current Rating - 2000 A
- EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Air Circuit Breaker
- Safety Function - Emergency Stop, Category 1 with Opening the Main Contactor/Breaker, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$1,833.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 12-Pulse, DSU
- Current Rating - 2000 A
- EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Earthing Switch
- Safety Function - None (Not Required)
- Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$1,841.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 4000 A
- EMC Filter - None (Not Required)
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Earthing Switch
- Safety Function - Emergency Stop, Category 1 with Opening the Main Contactor/Breaker, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$2,226.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 12-Pulse, DSU
- Current Rating - 4000 A
- EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Earthing Switch
- Safety Function - Emergency Stop, Category 1 with Opening the Main Contactor/Breaker, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$2,292.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 1060 A
- EMC Filter - 2nd Environment, C3, Grounded (TN) & Ungrounded Network (IT)*
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Earthing Switch
- Safety Function - Emergency Stop, Configurable Category 0 or 1 with STO & Safety Functions Module (FSO-12/-21)
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$2,418.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 12-Pulse, DSU
- Current Rating - 920 A
- EMC Filter - None (Not Required)
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Earthing Switch
- Safety Function - Emergency Stop, Category 0 with Opening the Main Contactor/Breaker, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$2,518.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 12-Pulse, DSU
- Current Rating - 1470 A
- EMC Filter - 2nd Environment, C3, Grounded (TN) & Ungrounded Network (IT)*
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Earthing Switch
- Safety Function - Emergency Stop, Category 1 with Opening the Main Contactor/Breaker, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$777.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 490 A
- EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Air Circuit Breaker
- Safety Function - Emergency Stop, Category 0 with STO, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$1,461.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 3000 A
- EMC Filter - 2nd Environment, C3, Grounded (TN) & Ungrounded Network (IT)*
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Earthing Switch
- Safety Function - None (Not Required)
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$1,821.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 1060 A
- EMC Filter - None (Not Required)
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Earthing Switch
- Safety Function - Emergency Stop, Configurable Category 0 or 1 with STO & Safety Functions Module (FSO-12/-21)
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$1,992.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 2000 A
- EMC Filter - None (Not Required)
- Output Filter - Common Mode Filter
- Incoming Unit Apparatus - Earthing Switch
- Safety Function - Emergency Stop, Category 0 with STO, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$137.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 12-Pulse, DSU
- Current Rating - 4000 A
- EMC Filter - None (Not Required)
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Air Circuit Breaker
- Safety Function - Emergency Stop, Category 0 with Opening the Main Contactor/Breaker, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$196.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 2000 A
- EMC Filter - None (Not Required)
- Output Filter - Common Mode Filter
- Incoming Unit Apparatus - Earthing Switch
- Safety Function - Emergency Stop, Configurable Category 0 or 1 with STO & Safety Functions Module (FSO-12/-21)
- Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$202.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 1470 A
- EMC Filter - None (Not Required)
- Output Filter - Common Mode Filter
- Incoming Unit Apparatus - Air Circuit Breaker
- Safety Function - Emergency Stop, Category 1 with Opening the Main Contactor/Breaker, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$299.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 1060 A
- EMC Filter - None (Not Required)
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Earthing Switch
- Safety Function - Emergency Stop, Category 0 with STO, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$531.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 1060 A
- EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
- Output Filter - Common Mode Filter
- Incoming Unit Apparatus - Air Circuit Breaker
- Safety Function - None (Not Required)
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$727.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 1470 A
- EMC Filter - None (Not Required)
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Earthing Switch
- Safety Function - Emergency Stop, Category 1 with Opening the Main Contactor/Breaker, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$835.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 12-Pulse, DSU
- Current Rating - 1470 A
- EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
- Output Filter - Common Mode Filter
- Incoming Unit Apparatus - Earthing Switch
- Safety Function - Emergency Stop, Category 1 with STO, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$873.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 4000 A
- EMC Filter - 2nd Environment, C3, Grounded (TN) & Ungrounded Network (IT)*
- Output Filter - Common Mode Filter
- Incoming Unit Apparatus - Air Circuit Breaker
- Safety Function - Emergency Stop, Configurable Category 0 or 1 with STO & Safety Functions Module (FSO-12/-21)
- Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$1,039.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 4000 A
- EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Earthing Switch
- Safety Function - Emergency Stop, Category 1 with STO, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$1,188.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 12-Pulse, DSU
- Current Rating - 2000 A
- EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
- Output Filter - Common Mode Filter
- Incoming Unit Apparatus - Air Circuit Breaker
- Safety Function - None (Not Required)
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$1,244.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 12-Pulse, DSU
- Current Rating - 920 A
- EMC Filter - 2nd Environment, C3, Grounded (TN) & Ungrounded Network (IT)*
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Air Circuit Breaker
- Safety Function - Emergency Stop, Category 1 with Opening the Main Contactor/Breaker, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$1,265.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 12-Pulse, DSU
- Current Rating - 2940 A
- EMC Filter - 2nd Environment, C3, Grounded (TN) & Ungrounded Network (IT)*
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Earthing Switch
- Safety Function - Emergency Stop, Configurable Category 0 or 1 with STO & Safety Functions Module (FSO-12/-21)
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$1,467.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 12-Pulse, DSU
- Current Rating - 1470 A
- EMC Filter - 2nd Environment, C3, Grounded (TN) & Ungrounded Network (IT)*
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Air Circuit Breaker
- Safety Function - Emergency Stop, Category 0 with Opening the Main Contactor/Breaker, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Earthed Mains, Standard
100+ In Stock
$1,709.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 12-Pulse, DSU
- Current Rating - 4000 A
- EMC Filter - None (Not Required)
- Output Filter - Du/dt Filters
- Incoming Unit Apparatus - Earthing Switch
- Safety Function - Emergency Stop, Configurable Category 0 or 1 with STO & Safety Functions Module (FSO-12/-21)
- Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$1,819.00 CAD
Does not ship to OH, United States
- Voltage - 690 V (Range 525-690 V)
- Pulse - 6-Pulse, Half-Controlled Diode Bridge
- Current Rating - 1470 A
- EMC Filter - 1st Environment, Restricted Distribution, C2, Grounded Network
- Output Filter - Common Mode Filter
- Incoming Unit Apparatus - Earthing Switch
- Safety Function - Emergency Stop, Category 1 with Opening the Main Contactor/Breaker, with Safety Relay
- Earth Fault Protection - Earth Fault Monitoring, Unearthed Mains
100+ In Stock
$1,850.00 CAD
Does not ship to OH, United States
Specifications
Brand
Voltage & Power Range
- Mains: 3-Phase, UN3 380-415 V, +10 %/-10 %
- Mains: 585 to 7,027 kVA
- Motor: 3-Phase output Voltage 0 to UN3 /UN5 /UN7
- Mains: 3-Phase, UN7 525-690 V, +10 %/-10 %
Frequency
- Motor: 0 to ± 598 Hz
- Mains: 50/60 Hz ± 5 %
Storage / Transport Temperature
- -40° to 70° C
Operating Temperature
- Liquid-Cooled: 45° to 55° C with Derating of 0.5 %/1° C
- Liquid-Cooled: 0° to 45° C, No Frost Allowed
Motor Control
- Direct torque Control (DTC)
Certifications & Approvals
- cULus Listed, CSA
- RCM, EAC
- TÜV
- RoHS
- LVD
- ATEX
- CE
- EMC
Environmental Protection
- IP54
- IP42
- IP22
Altitude
- 0 to 1,000 m, without derating
- 1,000 to 4,000 m, with derating of 1 %/100 m
Humidity
- 5 % to 95 % RH, No Condensation
Documentation
Certificate
- ACS880-x4 (frames R8i), -04XT, -04FXT, -x7(LC), -x04, -x04LC, -x07 and multidrives, EU Declaration of Conformity pdf 3.9 MB
- EU Declaration of Conformity, According to LVD 2014/35/EU and EMCD 2014/30/EU, ACS880-107, -107LC, -207, -207LC, -307, -307LC, -607, -607LC -907, -1007LC, -1607, -1607LC pdf 1.6 MB