LMT200.N2.S6.C3.B1.D1.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.

Series: LMT200 External Mount Magnetostrictive Level Transmitter Brand: ABB Group
Price
$2,330.00 CAD
Stock
50+ In Stock

  • Approvals - North American (Meeting FM and Canadian Standards) Explosion Proof/Flameproof
  • Probe Material - 316/L SS
  • Probe Style and Probe Type - 3/4" NPS Sensor Well with 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121.11° C (–320° to 250° F), with N2 Purge. See Temperature Chart for Full Selection Detail*
  • Mounting Orientation - Bottom Left Connected Electronic Housing
  • Housing - Aluminum with 2 x M20 x 1.5
  • Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
  • Output - Single 4-20 mA + HART
  • SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
  • Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
  • Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
  • Signal Cable Length - 10 m (Approx. 33 ft)
  • Surge Protector - Surge/Transient Protector
  • Special Other - Special Paint or Treatment on Housing
  • Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
  • Certificate - None
  • Drawings - Drawings for Approval Required Prior to Construction
  • Documentation Language - English
  • Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
  • Measuring Length - Customized Insertion Length in inches

Specifications

Brand

Accuracy

  • ± 0.01 % of Full Scale or ± 1.27 mm, Whichever is Greater

Repeatability

  • ± 0.005 % of Full Scale or 0.315 mm (0.012 in), Whichever is Greater

Non-Linearity

  • ± 0.01 % of Full Scale or 0.86 mm (0.034 in), Whichever is Greater

Measuring Span

  • Minimum 76.2 mm (3.0 in)

Process Pressure

  • Up to 165.48 bar (2,400 psig)
  • Standard -1 to 124.1 bar (-14.7 to 1,800 psig)

Process Temperature

  • -195.5° to 426.6° C (-320° to 800° F)

Communication

  • FOUNDATION Fieldbus
  • HART

Enclosure/Body Material

  • Enclosure: Cast Low Copper Aluminum with Powder Coat
  • Enclosure: 316/L Stainless Steel

Supply Voltage

  • 9.0-32 Vdc for FOUNDATION Fieldbus
  • 12-43 Vdc for 4-20 mA HART Loop Powered

Ambient Temperature

  • -40° to 85° C (-40° to 185° F)

Humidity

  • 0 to 100 % Relative Humidity

Remote Transmitter

  • Standard Remote Distances of 5 m (16 ft), 10 m (33 ft), 20 m (66 ft), 30 m (98 ft)

Environmental Protection

  • IP66, NEMA 4X

Certifications & Approvals

  • SIL 2/3
  • FM
  • KOSHA
  • EAC
  • ATEX/IECEx
  • NEPSI
  • INMETRO

Material of Construction

  • Sensor Tube: 316/L Stainless Steel

Probe Length

  • 304.8 mm to 15.24 m (1 to 50 ft)
  • 90 Degree Probes (SEH Option) 304.8 mm to 7.62 m (1 to 25 ft)

Mounting

  • Stainless Steel Clamps for KM26 Magnetic Level Gauge Chamber Included, Optional Vibration Isolation Mounts

Electrical Connection

  • Two M20 x 1.5 or Two 1/2” FNPT, Adapters and Bus Connectors Also Available

Damping

  • Field Adjustable 0.1 to 60 s

Documentation

Certifications

show more