Price
$606.00
CAD
Stock
25+ In Stock
- Range - 0 to 5.000 ppm
- Number of Streams - Measuring 3 Streams
- Communication - None
- Enclosure - Standard
- Power Supply - 96 to 264 Vac, 50/60 Hz
- Manual - Spanish
- Certification - None
Specifications
Brand
Measurement Range
- 0 to 5 ppm Fe (0 to 5 mg/L)
Accuracy / Maximum Measured Error
- ± 5 % of Reading or ± 0.005 ppm, whichever is greater
Repeatability
- ± 5 % of Reading or ± 0.005 ppm, whichever is greater
Resolution
- 0.001 ppm or 1 ppb
Calibration
- 2-Point, Automatic Calibration
Operating Temperature
- 5° to 45° C (41° to 113° F)
Sample Temperature
- 1° to 40° C (32° to 104° F)
Sample Pressure
- 5 psi Max.
Flow Rate
- Sample: Continuous 200 to 500 mL/min
Display
- Color, TFT, LCD with built-in backlight and brightness Adjustment
Environmental Protection
- IP 31
Power Supply
- 18-36 Vdc optional
- 100-240 Vac Max. 50/60 Hz ± 10 %
Power Consumption
- 100 W Max. - DC
- 75 W Max. - AC
Materials of Construction
- Door: Acrylic
- Lower Tray: 20 % Glass-loaded Polypropylene
- Main Enclosure: Noryl
- Electronics Enclosure: 10 % Glass-loaded Polycarbonate
Communication
- PROFIBUS DP V1.0
Certifications & Approvals
- CE
- cULus
- EMC
- LV Directives