ABB Advanced Emission Gas Monitoring System for Marine Applications

Price
$2,009.00 CAD
Stock
50+ In Stock

Specifications

Brand

Certifications & Approvals

  • DNV GL
  • ClassNK
  • Korean Register of Shipping (KR)
  • ABS Group
  • Bureau Veritas
  • Lloyd's Register

Operating Temperature

  • 5° to 55° C (41° to 131° F)

Environmental Protection

  • IP54

Measurement Range

  • CO (Option): 0 to 500 ppm
  • O₂ (Option): 0 to 25 Vol %
  • SO₂: 0 to 250 ppm, 0 to 500 ppm
  • CO₂: 0 to 20 Vol %

Temperature Range

  • Sample Gas inlet: Max. 500° C (932° F)

Pressure Range

  • Instrument Air inlet: 400 to 600 kPa (60 to 90 psig)
  • Sample Gas inlet: 850 to 1100 hPa (0.85 to 1.1 bar), (12.3 to 16 psi)

Air Consumption

  • < 0.2 Nm³/day

Linearity

  • < 2 % of Reading or Max. 0.3 % of Span whichever is greater

Precision

  • For Measuring Ranges > 100 ppm: 100 ppm: < ± 1 % of Span
  • For Measuring Ranges < 100 ppm: < ± 2 % of Span

Drift

  • Span Drift SO₂, CO₂: ≤ 2 % of measured value per week
  • Zero Drift SO₂, CO₂: ≤ 2 % of Span per week

Warm-Up Time

  • 30 minutes (with thermostat)

Material of Construction

  • Painted Electro Galvanized (EG) Steel

Mounting

  • Wall Mounted / Rack Mounted

Power Supply

  • 230 Vac, ± 10 %, 50 to 60 Hz, ± 3 Hz

Power Consumption

  • Heated sample gas line: Approximately 90 W/m
  • Sampling probe: 300 W
  • Air conditioner: 1,600 W
  • System cabinet: 500 W

Communication

  • Modbus
  • RS-232 Interface
  • Ethernet
show more