ABB Natural Gas Chromatograph
Price
$2,312.00
CAD
Stock
50+ In Stock
As an extension of the NGC8206, the NGC8106 introduces a new paradigm by allowing real-time measurement at lower volume stations where it was previously cost-prohibitive to put a GC!
The NGC8106 performs on-site, real-time gas analysis and heating value computation.
The 8106 can be used as a total energy meter with the addition of a multivariable transmitter!
The NGC8106 is a perfect replacement for automatic samples.
The user will enjoy realtime data instead of monthly averages, and shipping and handling errors have been virtually eliminated.
Features- Compact design
- Extreme serviceability
- Low installation costs
- Low utility requirements
- Low maintenance
- Unmatched performance
Specifications
Brand
Environmental Protection
- NEMA /Type 4X/IP56
Media
- Helium (Consumption rate typically < 20 cc/minute during analysis cycle)
Repeatability
- ± 0.05 % over Temperature
- ± 0.025 % @ ambient
Storage Temperature
- -22° to 140° F (-30° to 60° C)
Temperature Range
- Cold Weather Enclosure: -40° to 130° F (-40° to 55° C)
- Normal 0° to 131° F (-18° to 56° C)
Supply Voltage
- 10.5-16 Vdc (Optional 21-28 Vdc)
Power Consumption
- Start up: 45 W at 15 Vdc, less than 3 A @ 0° F (-18° C)
- Nominal: 7 W at 15 Vdc, 650 mA @ 0° F (-18° C)
Certifications & Approvals
- IECEx Exd IIB + H₂ T6, Class I, Zone 1
- EMC - EMI/RFI: EN 55022, EN 61000-6-1, EN 61000-4-2, 4-3, 4-4, 4-6, 4-8, CISPR 22-200
- CE: ATEX II 2G: Ex d, IIB+H₂ T6, Class I, Zone 1
- NEC & CEC Class I, Div. 1, Groups B, C and D, T6: CFR 47, Part 1
Communication
- Two Serial Digital Ports, Software selectable for RS-232, RS-485, or RS-422
- One USB MMI. USB hub (Host and client) and Ethernet Ports
Protocols
- Modbus ASCII or RTU
- OPC
- Modbus / TCP Server
- Modbus / TCP Client
Dimensions
- 6.75” diameter x 16” long x 9.00” tall
- 17.1 cm x 40.6 cm x 22.9 cm
Weight
- Approximately 28 lb (12.7 kg)
- Shipping: Approximately 47 lb (21.3 kg)
Documentation
Brochure
- Course description - NGC, PGC1000 Level Two pdf 348 KB
- Course description - Remote Learning - NGC, PGC1000 Fundamentals pdf 188 KB
- Field service and training options pdf 319 KB
- Totalflow Analyzer Products pdf 22.9 MB
- Course description - NGC, PGC1000 Level One pdf 180 KB
- Introducing the NGC8106 pdf 370 KB
- NGC Liquid Injection System pdf 819 KB
- NGC8106 | Composite sampler replacement pdf 164 KB
- Totalflow 2017 Policy Information pdf 104 KB
- Upstream Oil and Gas pdf 3.9 MB
Catalog
Certificate
Manual
- Startup guide - NGC 8106 Natural Gas Chromatograph pdf 1.5 MB
- Technical Bulletin 175 - PCCU Vista Mobile Device Center Installation pdf 118 KB
- Technical bulletin 201 - Windows Mobile Device Center will not open to allow connection to ABB NGC after upgrading to Windows 10 pdf 806 KB
- NGC 8106 Natural Gas Chromatograph pdf 7.8 MB