MBS 4500 Pressure Transmitter
Brand: DanfossThe high accuracy pressure transmitter MBS 4500 is designed for use in almost all industrial applications, and offers a reliable pressure measurement, even under harsh environmental conditions.
The flexible pressure transmitter programme covers a 4-20 mA output signal, absolute or gauge (relative) versions, measuring ranges from 0-1 to 0-600 bar zero and span adjustment. A rotatable plug connection and a wide range of pressure connections.
Excellent vibration stability, robust construction, and a high degree of EMC/EMI protection equip the pressure transmitter to meet the most stringent industrial requirements.
Features- Designed for use in severe industrial environments
- Enslosure and wetted parts of acid-resistant stainless steel (AISI 316L)
- Pressure ranges in relative (gauge) or absolute from 0 up to 600 bar
- Output signal: 4-20 mA
- A wide range of pressure connections
- Temperature compensated and laser calibrated
- Accuracy 0.5% FS
- Zero and span adjustment
Specifications
Brand
Accuracy
- ≤ ± 0.2 % of Full Scale - Typical Including Non-Linearity, Hysteresis & Repeatability
- ≤ ± 0.5 % of Full Scale, Max.
Ambient Temperature Range
- -40° to 85° C (-40° to 185° F)
Applications
- Harsh Environments
- Industrial Applications
- Reliable Pressure Measurement
Approvals & Certifications
- CE
- EMC
BSP Connection
- G 1/2” A Male
- G 1/4” A Male
- G 3/8” A Male
Burst Pressure
- 6 x Full Scale [psi: 29,010 (MPa: 200, bar: 2,000) - Max.
Compensated Temperature
- 0° to 80° C (32° to 176° F)
Current
- 28 mA Typical - Current Limitation (Linear Output up to 1.5 x Rated Range)
Electrical Connectors
- DIN 3852 Form E
- DIN 3869-14
- Plug PG9 as Per EN 175301-803-A
Electrical Protection
- Polarity
- Short Circuit
Enclosure, Body Material
- AISI 316L Stainless Steel, 1.4401
Environmental Protection
- IP65
Gasket Material
- NBR
Hysteresis
- ≤ ± 0.1 % of Full Scale
Insulation Resistance
- > 100 megaohms at 100 V
Materials of Construction
- Glass-Filled Polyamid, PA 6.6 - Electrical Connection Material
Non-Linearity
- ≤ ± 0.2 % of Full Scale - BFSL (Conformity)
NPT Connection
- 1/2”-14 Male NPT
- 1/4”-18 Male NPT
Output
- 4-20 mA - Nominal Output Signal (Short-Circuit Protected)
Overpressure & Static Pressure Limits
- 6 x Full Scale [psi: 21,760 (kPa: 150,000, bar: 1,500) - Max.
Pressure Range
- bar: 0 to 600
- kPa: 0 to 60,000
- psi: 0 to 8,700
Pressure Type
- Absolute
- Gauge
Process Temperature
- 115° C (239° F)
Repeatability
- ≤ ± 0.1 % of Full Scale
Response Time
- < 4 milliseconds
Shock
- 1 metre Free Fall as Per IEC 60068-2-32
- 500 G, 1 millisecond as Per IEC 60068-2-27
Span & Zero Adjustments
- -2.5 to 5 % of Full Scale - Zero Point Adjustment
- -5 to 10 % of Full Scale - Zero Point Adjustment
- -5 to 20 % of Full Scale - Zero Point Adjustment
- -5 to 5 % of Full Scale - Span Adjustment
Span & Zero Effect
- ≤ ± 0.1 % of Full Scale/10K Typical - Thermal Zero Point Shift & Span Shift
- ≤ ± 0.2 % of Full Scale/10K, Max.
Storage Temperature
- -50° to 85° C (-58° to 185° F)
Supply Voltage
- ≤ ± 0.1 % of Full Scale/10 V - Supply Voltage Dependency
- 10-30 Vdc - Polarity Protected
Temperature Range
- -40° to 85° C (-40° to 185° F) - Normal Temperature for Sensor
Torque
- 30 to 35 Nm (265 to 310 In/Lbs)
Vibration
- Random Vibration: 7.5 G RMS, 5 to 1,000 Hz as Per IEC 60068-2-64
- Sinusoidal Vibration: 15.9 mm-pp, 5 to 25 Hz as Per IEC 60068-2-6
- Sinusoidal Vibration: 20 G, 25 to 2,000 Hz as Per IEC 60068-2-6
Wetted Materials
- 316L Stainless Steel, 1.4401
- Reliable Pressure Measurement
- Harsh Environment
- Industrial Applications